FAULT FINDING

FAULT: PUMP RUNS ALL THE TIME.
1. Is there debris/Biofilm slime on the float
sensor? (This may occur if pump has
been in operation for some time without
cleaning. Clean using an anti-
bacterial wash.)
2. Is there debris/Biofilm slime present
within the reservoir? (This may occur if
pump has been in operation for some
time without cleaning. Clean using an
anti-bacterial wash.)
3. Check the floats are free to move up
and down.
If you have any queries, please contact our Technical team for further advice.
+44 (0)1323 848842 Email: technical@aspenpumps.com
WEEE DIRECTIVE WARNING
Meaning of crossed out wheeled dustbin
Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for information regarding the
collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food
chain, damaging your health and well-being. When replacing old appliances with new ones, the retailer is legally obligated to take back your old appliance for
disposals at least free of charge.
FAULT: PUMP RUNS BUT DOES NOT
PUMP ANY WATER.
1. Are there any air-locks in the pipe running
to the pump?
2. Are any of the outlet pipe, inlet pipe,
bleed pipe and waste pipe blocked?
3. Check that reservoir, filter, bleed pipe,
inlet and outlet tube are free of sludge
and debris.
7
FAULT: PUMP ISN'T OPERATING AT ALL.
1. Is power reaching the pump? Is it
correctly wired? Is the voltage correct?
2. Is the pump very hot? A thermal cut-out
may have been activated to protect
pump. This will automatically reset once
pump has cooled down.
3. Is the supply voltage within the specified
range (230 VAC 50Hz)?