GEZE Slimchain 230V AC Manual De Instrucciones página 22

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 41
Slimchain 230 V AC
1. Open the cover for the mains connection
on the drive and loosen the strain relief.
®
Torx
TX10
3. Disconnect the cable from the connector
and connect the new connection cable
using wire end ferrules.
5. Fit the cover and screw in place.
Screw tightening torques:
à Cover for mains connection: Torx ®T10, 0.7-0.9 Nm
à Strain relief: Cross slot PZ1, 0.9-1.1 Nm
PZ1
Routing cables and electrical connection
2. Unplug the cable with connector vertically.
4. Plug in the connector with new cable and
fit the strain relief.
EN 9

Publicidad

Tabla de contenido
loading

Tabla de contenido