Setting The Parameters Of The Drive; Operating Modes - GEZE Slimchain 230V AC Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 41

Setting the parameters of the drive

9
Setting the parameters of the drive
Parameters can be set for the drive using the LIN parameter setting adapter
(GEZE mat. no. 179238) and the parameter setting device ST 220 (GEZE mat.
no. 087261). To do this:
X
Open the service cover and insert the parameter setting adapter
X
Connect the drive to 230 V and operate in the "CLOSE" direction
X
Wait until the drive has reached the "CLOSE" end position
X
Carry out parameter setting using ST 220
GN
LIN
BN
+24 V
FSE 301
LIN
GND
WH
cable
GN
green
BN
brown
WH white
The possible projection range for the drives is 8-23 mm.
In the case of windows with a projection > 23 mm the drive stroke must be
reduced.
Further information about parameter setting can be found in the inst-
ructions GEZE mat. no. 153523 for the parameter setting device.
10

Operating modes

Operating mode ventilation
Drive opens at ventilation speed up to ventilation stroke
EN 12
L
B
A
LIN parameter setting adapter
Slimchain 230 V AC
ST 220
ST 220
Connection cable
Pin strip for connecting the
LIN parameter setting adapter

Publicidad

Tabla de contenido
loading

Tabla de contenido