Light Switch 5
L
Light Switch 2
M
N
10b
L
Light Switch
Connection Detail
13. On Zettler light relay 2, disconnect the 12 AWG wire
(O, Figure 11) from the AC light switch spade, and
this wire was just reconfigured on the light switch 1.
On Zettler relay 1, disconnect the wire leading from
light switch 5 from the same spade. On Zettler relay
3, disconnect the wire leading from light switch 4 for
6-light units or from light switch 2 for 4-light units from
the same spade.
11
Zettler Relay
Disconnection Detail
Light Switch 3
Light Switch 1
Light Switch 4
Light Switch 6
Light Switches Detail
Light Switch 1
Zettler Relay 2
O
14. Cut off and discard the female spade terminal from
the wire that was connected to the Zettler relay. Strip
off the appropriate amount of wire insulation and crimp
a yellow fork terminal (P, Figure 12, Ref. 7) onto the
wire.
12
P
15. Loosen the screw on AC post 1 of 725 light relay 1
and connect the new fork terminal on the wire (Q,
Figure 6a-b) removed from either Zettler relay 1, 2, or
3 into the post. Tighten down the screw onto the fork
terminal.
13
16. Take the cut 10 AWG wire (R, Figure 14) that was set
aside in Step 9 and crimp a yellow fork terminal (S,
Figure 14, Ref. 7) on one of the ends. On the other
end, crimp on the terminal ring (T, Figure 14, Ref. 6).
14
T
725 Relay 1
Q
R