4b
Zettler Relay
Disconnection Detail
7. Cut off and discard the female spade terminal from
the wire that was connected to the Zettler relay. Strip
off the appropriate amount of wire insulation and crimp
a yellow fork terminal (F, Figure 5, Ref. 8) onto the
wire.
5
F
8. Loosen the screw on AC post 1 of 725 light relay 1 and
connect the new fork terminal on the wire (G, Figure
6a-b) removed from either Zettler relay 1 or 2 into the
post. Tighten down the screw onto the fork terminal.
9. On Zettler light relay 2, disconnect the 12 AWG wire
(H, Figure 6a-b) from the AC light switch spade, and
this wire was just reconfigured on the light switch 3.
On Zettler relay 1, disconnect the wire leading from
light switch 1 from the same spade.
4
Zettler Relay 2
E
6a
H
6b
Zettler Relay 2
H
Relay Connection
and Disconnection Detail
10. Cut off and discard the female spade terminal from
the wire that was connected to the Zettler relay. Strip
off the appropriate amount of wire insulation and crimp
a yellow fork terminal (I, Figure 7, Ref. 8) onto the wire.
7
I
Zettler Relay 2
725 Relay
G
725 Relay
G
www.allmand.com