In the event of scratches or considerable damage, it is necessary to
contact authorized service centres.
D
GLASS PANELS
Glass surfaces can be cleaned with normal, commercially available
products for this purpose.
CLEANING THE THERMOSTATIC VALVE
The thermostatic valve is provided with mesh filters to trap any impu-
rities in the water. Over time, these filters could become clogged and,
therefore, inhibit the functions of the mixer tap. To clean them, do the
following:
I Turn off the water supply (hot and cold) to the shower enclosure.
I Empty the water from the mixer unit, by turning the diverter di-
al (G) to the symbol "D - bottom jets" and turning on the stop tap
(R) completely. Then turn off the stop tap again, turning the dial
to the previous position.
I (1) Remove the plug (T) from the knob of the mixer.
I (2-3-4) Remove the screw (V), slide off the knob (M) and the
cap of the mixer (C).
I (5) Unscrew the ring nut (H) that secures the thermostatic valve.
I (6) Ease out the thermostatic valve (L).
Clean the mesh filters with a little brush and rinse. If scale is present,
wash with specific products.
I (7) Replace the various components following the same procedure
in reverse order.
I (8) Fasten the thermostatic valve so that the screw peg (Q) is
facing downwards, and that it fits into the groove of the brass com-
ponent.
14