Alarm
Cause
Steam sensor
This alarm is triggered when the MCS
interrupted
temperature sensor is out of range
Steam
This alarm is triggered when the MCS
sensor failure
temperature sensor is out of range
(short circuit)
Gp.1
This alarm is triggered when
sensor timeout
brew group 1 has not reached the
temperature of 50 °C within 5 minutes
from being activated
Gp.1
This alarm is triggered when the brew
sensor
group 1 temperature sensor is out of
interrupted
range
Gp.1
This alarm is triggered when the brew
sensor
group 1 temperature sensor is out of
short circuited
range
High
This alarm is triggered when the tempe-
temperature
rature of brew group 1 has gone above
Gp.1
120 °C
Effect
The MCS function is blocked;
tap DEL on the display
to cancel the alarm
The MCS function is blocked;
tap DEL on the display
to cancel the alarm
Brew group 1 heating
blocked; tap DEL on the
display to cancel the alarm
Brew group 1 heating
blocked; tap DEL on the
display to cancel the alarm
Brew group 1 heating
blocked; tap DEL on the
display to cancel the alarm
Brew group 1 heating
blocked; tap DEL on the
display to cancel the alarm
| 107