Alarm
Cause
Gp.2
This alarm is triggered when brew group 2
sensor
has not reached the temperature of 50 °C
timeout
within 5 minutes from being activated
Gp.2
This alarm is triggered when the brew
sensor
group 2 temperature sensor is out of range
interrupted
Gp.2
This alarm is triggered when the brew group
sensor
2 temperature sensor is out of range
short circuited
High
This alarm is triggered when the temperature
temperature
of brew group 2 has gone above 120 °C
Gp.2
Gp.3
This alarm is triggered when brew group 3
sensor
has not reached the temperature of 50 °C
timeout
within 5 minutes from being activated
Gp.3
This alarm is triggered when the brew
sensor
group 3 temperature sensor is out of range
interrupted
108 |
Effect
Brew group 2 heating
blocked; tap DEL on the
display to cancel the alarm
Brew group 2 heating
blocked; tap DEL on the
display to cancel the alarm
Brew group 2 heating
blocked; tap DEL on the
display to cancel the alarm
Brew group 2 heating
blocked; tap DEL on the
display to cancel the alarm
Brew group 3 heating
blocked; tap DEL on the
display to cancel the alarm
Brew group 3 heating
blocked; tap DEL on the
display to cancel the alarm