Suitability For Use; Safety Precautions - Omron E5AR Hoja De Instrucciones

Ocultar thumbs Ver también para E5AR:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

EN
Introduction
Thank you for purchasing this OMRON product.
Read this instruction manual and thoroughly familiarize yourself with the functions and
characteristics of the product before using it. This product is designed for use by qualified
personnel with knowledge of electrical systems. Keep this instruction manual for future reference.
This manual contains instructions for installing the product and information on basic operation.
For information on applications and explanations of the setting datas, see the User's Manual. To
obtain the User's Manual and other advanced information, see "Detailed Information" on page 10.

Suitability for Use

OMRON shall not be responsible for conformity with any standards, codes, or
regulations which apply to the combination of the products in the customer's
application or use of the product.
At customer's request, OMRON will provide applicable third party certification
documents identifying ratings and limitations of use which apply to the product.
This information by itself is not sufficient for a complete determination of the
suitability of the product in combination with the end product, machine, system, or
other application or use. Customer shall be solely responsible for determining
appropriateness of the particular product with respect to customer's application,
product or system. Customer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS
RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A
WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE
OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE
INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

Safety Precautions

Definition of Precautionary Information
Indicates a potentially hazardous situation which, if not avoided, will result in minor
WARNING
or moderate injury, or may result in serious injury or death. Additionally there may be
significant property damage.
Indicates a potentially hazardous situation which, if not avoided, may result in minor
CAUTION
or moderate injury or in property damage.
Precautionary Information
Always provide protective circuits in the network. Without protective circuits, malfunctions may
possibly result in accidents that cause serious injury or significant property damage.
Provide double or triple safety measures in external control circuits, such as emergency stop
circuits, interlock circuits, or limit circuits, to ensure safety in the system if an abnormality occurs
due to malfunction of the product or another external factor affecting the product's operation.
1
WARNING
Do not touch the terminals while power is being supplied. Doing so may occasionally
result in minor injury due to electric shock.
Do not touch the terminals or the electrical components or patterns on the PCB within 1
minute after turning OFF the power supply. Doing so may occasionally result in minor
injury due to electric shock.
Do not allow pieces of metal, wire clippings, or fine metallic shavings or filings from
installation to enter the product. Doing so may occasionally result in electric shock, fire, or
malfunction.
Do not use the product in locations where flammable or explosive gases are present.
Doing so may occasionally result in minor or moderate explosion, causing minor or
moderate injury, or property damage.
Tighten the screws on the terminal block and the connector locking screws securely using
a tightening torque within the following ranges. Loose screws may occasionally cause fire,
resulting in minor or or moderate injury, or damage to the equipment.
T
Perform correct setting of the product according to the application. Failure to do so is may
occasionally cause unexpected operation, resulting in minor or moderate injury, or
damage to the equipment.
Ensure safety in the event of product failure by taking safety measures, such as installing
a separate overheating alarm system. Product failure may occasionally prevent control
operations or alarm output, resulting in damage to the connected facilities and equipment.
Do not use the equipment for measurements within measurement categories II, III, or
IV(according to IEC61010-1). Doing so may occasionally cause unexpected operation,
resulting in minor or moderate injury, or damage to the equipment. Use the equipment for
measurements only within the measurement categories for which the product is designed.
The service life of the output relays depends on the switching capacity and switching
conditions. Consider the actual application conditions and use the product within the rated
load and electrical service life. Using the product beyond its service life may occasionally
result in contact welding or burning.
Make sure that the product will not be adversely affected if the DeviceNet cycle time is
lengthened as a result of changing the program with online editing. Extending the cycle
time may cause unexpected operation, occasionally resulting in minor or moderate injury,
or damage to the equipment.
Before transferring programs to other nodes or changing I/O memory of other nodes,
check the nodes to confirm safety. Changing the program or I/O memory of other nodes
may occasionally cause unexpected operation, resulting in minor or moderate injury, or
damage to the equipment.
Do not attempt to disassemble, repair, or modify the product. Doing so may occasionally
result in minor or moderate injury due to electric shock.
CAUTION
2

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

E5er

Tabla de contenido