If you do not want to use this transmitter as the individual control:
- cut the power supply (2 seconds minimum).
- repeat the opération 3.1* with a new transmitter and then go to step §4.
* In this case, the motor will run for 0,5 second in both directions, that means the limits setting is already done.
Programming the fi rst individual control point
4
This operation can only be performed from the transmitter that was used for operation 3.1.
- Press the transmitter PROG Key for approximately one second. The motor will run for 0,5 second in one direction and
then in the other. Your transmitter is now programmed to control the AUTO Hz motor in stable mode.
Programming a new (individual, group or general) control point
5
5.1- Open the memory of the receiver from the control transmitter:
- Press the PROG key of the transmitter for about 3 seconds. The motor will run for 0,5 second in one direction and then in
the other.
5.2- Confi rm the operation from the new transmitter you want to program:
- Press the PROG key of the transmitter for 1 second. The motor will run for 0,5 second in one direction and then in the
other.
- For group controls, repeat operations 5.1 and 5.2 for each motor in the group.
- For general controls, repeat operations 5.1 and 5.2 for each motor in the installation.
- To delete an transmitter from the memory of a motor, perform operations 5.1 with a programmed transmitter, then perform the operation 5.2 with the transmitter to be deleted.
Recording / controling / deleting intermediate position
6
Recording:
- Move the motor to the wanted position.
- Press 5 seconds on the «stop» key. The motor will run for
0,5 second in one direction and then in the other.
5s
Deleting:
- Position the motor on the intermediate position. Press 5 seconds on the Stop key, the intermediate position is deleted.
Modifi cation of the rotation direction (in user mode):
7
1.
5 s.
>>
After stage 7.1, if no operation is carried out before 3 seconds, the motor runs again briefl y in one direction and then in the other, and the rotation direction is not changed.
Cancelling programming
8
8.1
8.2
8.3
OFF
ON
2s
7s
If you switch on/off the power to several motors, they will all be in the cancellation mode. That is why you must "drop" all the motors that are not to be cancel-
led by controlling them from their individual control transmitter.
8.5
>>
PROG 7s
Warning: after stage 8.4, if nothing is done within 2 minutes, the motor will run again for 5 seconds in the direction opposite to that of 8.4.
Hereby, SIMU, declares that this equipment "T5 AUTO Hz" is in compliance with the essential requirements and other relevant provision of Directive
2006/42/EC. A declaration of Conformity is available at the web address: www.simu.com, heading "Normes". Usable in UE, CH.
2.
3 s.
>>
2 s.
8.4
OFF
ON
2s
5s
8.5 - Confirm the cancellation of the affected receiver from the individual control transmitter:
- Press the Prog key of the individual control transmitter for more than 7 seconds. The motor will first run for
>>
half a second in one direction and then in the other. A few seconds later, it will run again in the two directions. The
receiver is now as it was originally configured, and no transmitter and no settings is saved in its memory and is
ready for a new programming.
0,5s
Do not move the roller shutter to the up or down end limit position.
1 - Press the Up and Down buttons simultaneously for 5 seconds. The motor runs briefl y in one
direction, then in the other.
2 - Within 3 seconds, press the Stop button for 2 seconds. The motor briefl y runs in one direction,
then in the other. The rotation direction has been changed.
8.1 - Switch off the power supply to the motor for 2 seconds.
8.2 - Switch the power to the motor back on for 7 seconds.
8.3 - Switch off the power supply to the motor for 2 seconds.
8.4 - Switch the power to the motor back on.
- If the motor is on the end limit position (up or down), the motor will run briefly on one direction and then in
the other, otherwise, the motor runs for 5 seconds in random direction.
The motor is now in the "cancelling" mode.
1
PROG 1s
1
PROG
2
Control:
- Press the «stop» key for 0,5 second. The motor runs to
the intermediate position.
>>
>>
>>
1s
2/ 2