Installation instruction
4. Installation of the bus cable
-
At the rear side of the UV Plus the connection
box with the control pcb is located.
(page 69).
-
A bus cable is connected to the control pcb and
guided through the cable gland of the connec-
tion box. An additional cable gland is
installed to the bus cable.
-
There are knock outs in the bottom of the elec-
tric compartment. Break one of these out. Run
the bus cable of the UV Plus through this knock
out and fix the cable gland to it.
-
Additionally fix shielding plate (item 11) to
cable gland and connect it to the shield of the
bus cable (cut out insulation of the bus cable)
-
Connect the bus cable to the unit:
on electric units at a free connector of the
motor control
-
The cable can be affixed to the back of the
appliance with the self-adhesive cable clips
(pic.1 item 3) supplied.
5. Drain for condensation water.
On the rear side of the UV Plus a drain
connection for condensation water is installed
-
Fit the silicone hose (pic 1 item 4) with the hose
clamp (pic 1 item 5) to the elbow.
-
Put the drain pipe (pic 1 item 6) to the drain
of the unit.
-
Shorten the silicone (pic 1 item 4) hose to the
desired length and connect it to the drain
pipe (pic 1 item 6).
6. Electrical connection of the UV Plus
Danger
Observe local regulations and standards
during installation
pic. 10
Warning
Observe colour coding of the wires. Wrong
connection can cause electric shock
pic. 11
Attention:
Wrong connection can cause damages (e. g. fan
motor)
pic 10
Colour coding of wires:
yellow/green = earth
blue = neutral
pic. 12
black = Phase
-
The UV Plus must be connected to a standard
mains in accordance with the local regulations.
-
Before pulling the plug or reconnecting to the
power supply, make sure that the SelfCooking
Center or the Combi Master is switched off to
avoid that the UV Plus starts to run.
-
A permanent connection shall be provided for
the UV Plus. On-site installation: provide
accessible all-pole disconnection device with
a minimum of a 3 mm contact gap. If the
pic. 13
UV Plus shall be connected with a plug make
sure that it is accessible
pic. 14
-
The UV Plus must be protected on site with a
maximum fuse of 16 A. The UV Plus is fitted
with a cable approx. 2 m in length without plug.
pic. 14
-
If the power cord shall be changed, the
quality of the cord must be at least
H05 RN-F 3x1,5 mm
-
In case the power cable must be changed use a
cable that matches your local standards.
In case the power cable must be changed use a
cable that matches your local standards.
The exchange of the power cable may only be
carried out by the manufacturer, his service
agents or similar qualified personal
2