L I M I T E D WA R R A N T Y
The ventilation slots must be kept clean and free of foreign materials, such as styrofoam and small particles detached
from the cut objects. Always remove foreign material from the grooves before using the tool. Otherwise, this can
result in poor engine cooling failure.
5. Store the machine after its operation
Keep the tool stowed and in an area free of moisture, out of the reach of children.
Maintenance
Disconnect the plug from the power source before performing maintenance.
1. Replace the cutting disc
Using a worn cutting disc can give a poor result. Replace it with a new one.
2. Screws
Verify that the screws are rmly tightened at regular intervals. This helps prevent risky situations.
3. Save the tool when you are no longer using it
4. Cleaning
Occasionally, clean dirt and dust from this machine with a blower.
5 troubleshooting
Inrush current can cause a voltage drop in a short time. In conditions from unfavorable power source, other equip-
ment could be a ected. If the impedance system of the power source is less than 0.2 Ohm, unpleasant disturbances
could occur.
6. Brushes
12