Care and Cleaning
Turn off the Zoneline and disconnect the power supply before cleaning.

Indoor/Outdoor Coils

The Indoor/Outdoor coils on the Zoneline should be
cleaned and checked regularly.
NOTE: When cleaning the coils do not use
acid-based coil cleaners. Care must be taken to
avoid bending the aluminum fins on the coils.
Indoor-Air Coil
Minor amounts of lint and dirt may pass through the
filter and collect on the indoor-air coil. These minor
accumulations can be carefully vacuumed away
with a brush attachment on a vacuum cleaner or
professionally cleaned.
Outdoor-Air Coil
The unit's outdoor-air intake and outdoor-air exhaust
paths must remain clear. Check the outdoor-air
exhaust frequently. Keep it free of all debris, snow, or
ice. The outdoor-air intake should also be kept free
of obstructions. Blocking the outdoor-air exhaust or
outdoor-air intake opening will reduce the efficiency of
your unit and could cause premature compressor failure.
Inspection and cleaning of the outdoor-air coils may
require the unit to be removed from the case and closet.
See servicing section of this manual for instructions
on how to remove the unit. Professional cleaning is
recommended for the inside surface of the outdoor coil.

Base Pan

In some installations, dirt or other debris may be blown
into the unit from the outside and settle in the base pan
(the bottom of the unit).
49-5000561 Rev. 1
Have the coils cleaned regularly.
In some areas of the United States, a "gel-like"
substance may be present in the base pan.
Check it periodically and clean, if necessary.
Outdoor coils