Wall Fires -
Models: SP420 & SP920
IMPORTANT: THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
Important Safety Advice:
When using electrical appliances, basic precautions should be followed
to reduce the risk of fire, electric shock, and injury to persons, including
the following:
If the appliance is damaged, check immediately with the supplier before
installation and operation.
Do not use this heater in the immediate surroundings of a bath, shower
or swimming pool.
Do not use outdoors.
Do not cover or obstruct the heater in any way. Overheating will result if
it is accidentally covered.
In the event of a fault unplug the heater.
Unplug the heater when not required for long periods.
The supply cord is recommended to be placed on the right hand side of
the heater. The heater can also be HARD wired - this is recommended if
the heater is recessed - see 'Recessed Installation'.
This appliance is not intended for use by children or other persons without
assistance or supervision if their physical, sensory or mental capabilities
prevent them from using it safely. Children should be supervised to
ensure that they do not play with the appliance.
If the supply cord is damaged it must be replaced by the manufacturer
or service agent or similarly qualified person in order to avoid a hazard.
Electrical
WARNING – THIS APPLIANCE MUST BE EARTHED
This heater must be used on an AC ~ supply only and the voltage marked on the
heater must correspond to the supply voltage.
Do not switch the appliance on until properly installed. Please read all the safety
warnings and operating instructions.
General
Unpack the heater carefully and retain the packaging for possible future use, in
the event of moving or returning the fire to your supplier.
Contents of Carton
Heater.
Wall fixing bracket.
Fixing screws and wall plugs.
Remote control and batteries ( 3 AAA's type).
Spare bulb.
Do not connect the heater to an electricity supply until it is installed on a wall
correctly - see 'Installation'.
When in operation there is a 300 watt heat output from the fuel effect, and an
additional 120 watt output when the heated glass panel is in operation.
The heater can be used remotely or manually - see 'Operation'.
General features of remote control are:
Activate/Deactivate heated glass panel.
The illumination of fuel effect can be increased or decreased.
Please note: Used in an environment where background noise is very low, it may
be possible to hear the motor which operates the flame effect. This is normal and
should not be a cause for concern.
Installation
Do not connect appliance until properly fixed to the wall and the Instruction
leaflet is read fully.
The minimum distances must be observed.
For installation of the appliance, care must be taken not to damage concealed
cables.
Please be careful while drilling the holes.
This model is designed to be permanently fixed to a wall at a minimum height of
300mm. The wall bracket must be fitted horizontally and the cable routed to the
bottom right of the heater as in Fig. 1.
A height of 600mm from bottom of heater to floor is recommended for optimum
viewing of fuel bed (see Fig. 2 for recommended fixing dimensions).
For optimum viewing mark the top four screw fixing positions on wall in accordance
with the recommended fixing dimensions - see Fig. 2. Drill holes with a 6mm drill
bit.
Fix the wall bracket using the plugs and screws provided - see Fig. 3.
Carefully lift the heater up ensuring that the top rear ledge of heater engages the
wall bracket and is sitting centrally positioned. - see Fig. 4 (b).
Rotate the bottom fixing bracket down. - see Fig. 4 (c).
Gently bring the heater level with the wall. - see Fig. 4 (d).
Mark the bottom hole position (see Fig. 5), remove the heater ensuring that the
- 1 -
bottom fixing bracket is rotated up.
Drill and fit wall plug.
Refit the heater to the wall fixing bracket (i.e. follow steps as in Fig. 4 a, b, c and
d) and rotate the bottom fixing bracket down again and use the screw provided to
permanently fix the heater in place.
The heater should not be connected until the instruction leaflet is read fully.
Recessed Installation
Please note that this appliance can also be wall-mounted so that it is recessed.
This can be installed in a large fireplace opening or a purpose built wall. See
Table 1 for size of recess required and hole fixing dimensions and Fig. 5a. This
fireplace insert does NOT require venting.
In order to ensure it's future safety in use, it is essential that this fire is
securely fixed to the wall.
IT IS IMPORTANT THAT THE FIXING DEVICE CHOSEN IS APPROPRIATE
TO THE WALL MATERIAL TO WHICH THE FIRE IS BEING FIXED. SOME
MODERN INTERNAL BUILDING MATERIALS ARE VERY LOW DENSITY
BLOCK AND REQUIRE SPECIALIZED FIXING DEVICES TO PROVIDE A
SAFE,SECURE INSTALLATION.
The installation of this fire should be carried out by a competent person. If in
doubt please consult your local builder.
This section provides step by step instructions for selecting a location and
preparing the site to install the fireplace into the following:
Existing Fireplace
1. Make sure that the fire is located on a flat surface.
2. Seal all draughts and vents to prevent chimney debris from falling onto the
Fireplace Insert. Do not install into an existing fireplace that is prone to
dampness.
3. Remove the fire front panel by following the steps as outlined in 'Lamp
Replacement' sections and Fig. 10 for SP4 and Fig. 12 for SP9.
4. Locate the 4 fixing holes, position the fire accordingly, and firmly fix the
appliance to the wall using the appropriate screws - see Fig. 5a.
5. Replace the front panel.
New Support Structure Construction
When planning where to position your purpose built support structure the following
steps must be observed:
1. Place the fire in the desired location to see how it will look in the room.
2. Mark the desired location for the new support structure in the room and
store the fire in a safe, dry and dust free location.
3. Using timber studs to support the fire, devise and construct a suitable
means of supporting the product within the wall partition and provide electrical
power for the fire to be HARD wired. For recommended sizes of height, width
and depth of opening for recess and hole fixing dimensions for each model -
see Table 1 and Fig. 5a.
4. When the structure is complete, remove the front panel of the fire by following
the steps as outlined in 'Lamp Replacement' sections and Fig. 10 for SP4 and
Fig. 12 for SP9.
5. Locate the 4 fixing holes, position the fire accordingly, and firmly fix using
the appropriate screws.
6. Replace the front panel.
Models
SP420
SP920
NOTE: The appliance should be HARD wired to an electrical power outlet when
placed in a recessed installation.
Please consult a qualified electrician for appropriate wiring requirements.
Manual Operation
The switches are located at the bottom right side of the heater.
The Standby Switch (Switch S1) must be first turned 'ON' and the AUTO/MAN
(Switch S2) switch set to 'MANUAL' to operate the manual controls - see Fig. 6.
Note : When the fire is put in Manual mode the first time the flame effect will
come on indicated by the Bottom neon coming on for 3 seconds - see Fig. 7.
Remote Operation
The standby switch (S1) must first be turned 'ON' and the 'AUTO/MAN' Switch
turned to 'AUTO'.
Note: It takes some time for the receiver to respond to the transmitter. DO NOT
PRESS the buttons more than once within two seconds for correct operation.
TABLE 1
A
B
X
Y
871
570
847
646
914
565
895
676
UK
Z
115
150

Publicidad