Continued type
Digital outputs
Rated load voltage
Design
Protection against incorrect
polarity
Output current per channel
Short circuit protection
Voltage drop at output
Output delay
signal change 0" to 1"
signal change 1" to 0"
Parallel switching of outputs
for increased performance
Protection against reverse
voltage
Limitig the inductive switch−
off voltage of connected
coils/solenoid valves
Electrical isolation
Inputs
Outputs
between the channels
to V
EL/SEN
Isolation
28
CPX−8DE−8DA
8 outputs as per IEC 1131, 24 V
V
OUT
Positive logic (PNP)
Yes
Max. 0.5 A (12 W lamp load),
no sum current limitation
Yes (electronic),
Response threshold > 0.5 A
1 V
With ohmic load:
< 200 s
< 200 s
Yes, max. 4 outputs (O0 ... O3 or
O4 ... O7) of the same module
Max. V
OUT
Typ. −16 V
None
None
Yes, with an intermediate supply or
manifold sub−base type CPX−GE−EV−Z
(M18), CPX−GE−EV−S−7/8−5POL,
...−Z−7/8−5POL or ...−Z−7/8−4POL
Tested with 500 V DC
Festo CPX−EA 0602b English