Repeated cleaning of tips can lead to removal of the conductive plating, which impairs the electri-
cal performance. However, keeping plunger tips free from contamination will ultimately ensure re-
liable test results and improve the life expectancy of the probe.
Remove loosened dirt particles from the working area using vacuum or suction after cleaning.
7.4)
Cleaning the test fixture
Clean the test fixture with a soft cloth and a mild detergent. For cleaning, do not use cleaners with
solvent or acidic content.
7.5)
Grease/lubricate the test adapter
Maintenance-free floating bearings and permanently lubricated deep groove bearings are in-
stalled in the test adapter to ensure that maintenance work is not required for these bearing com-
ponents. The cam tracks of the rear bearing blocks are greased. Long-term testing under full loads
show clearly that re-lubrication of these cam tracks is not required.
The gas pressure spring bearings (see picture below) should be serviced with a drop of sewing
machine oil every 50,000 strokes.
7.6)

Spare parts

All test fixture parts are listed in a parts list with part numbers that is enclosed with the assembly
drawings. You can order the part(s) you need from INGUN by stating the part number(s).
8)

Technical specifications

Contacting stroke:
Contact force:
Spring-loaded test probe installation height in stand-
ard model
Length of retention clamp in standard model
©
INGUN: Subject to technical changes without notice. E&OE.
Lubricate gas spring bearings
Manual test fix-
ture 2xxx
15 mm
2,000 N
10.5 mm (below), 16 mm (above)
60 mm
Manual test fix-
ture 3xxx
22 mm
2,000 N
32