BASIC - Error handling
Error
Cause and solution
code
E20-00
There is no software present in the control
E20-02
unit
E21-00
Download software to the SD card, insert
E21-06
the SD card into the control unit and turn
E21-08
on the machine. Replace the SD card, if
necessary.
E20-01
The SD card is not formatted
E21-01
Format the SD card in a PC as FAT and
download software to the SD card. Replace
the SD card, if necessary.
E20-03
The SD card has several files of the same
E21-02
name
Delete files on the SD card and reload
software.
E20-04
The control unit has tried to load more
data than there is room for in the memory
Reinsert the SD card or replace the SD card.
If this does not solve the problem, contact
Migatronic Service.
E20-05
Software on the SD card is locked for
E20-06
another type of control unit
Use an SD card with software that matches
your type of control unit.
E20-07
The internal copy protection does not
allow access to the micro-processor
Reinsert the SD card into the machine or
contact Migatronic Service.
E20-08
The control unit is defective
E20-09
Contact MIGATRONIC Service
E21-05
E20-10
The loaded file is defective
E21-07
Reinsert the SD card or replace the SD card.
E21-03
The welding program package does not
E21-04
match this control unit
Use an SD card with software that matches
your type of control unit.
Err GAS
Gas error
Check the gas supply.
Cancel the gas fault by briefly pressing any
key.
E02-04
CAN communication error
Check intermediary cable/plug
E11-20
Current sensor error
1. Check the current sensor
2. Contact MIGATRONIC service
Fault symbols
Temperature fault
The indicator is switched on, when the power source is
overheated. Leave the machine on until the built-in fan has
cooled it down.
Current fault
The indicator flashes when start current or welding current
is higher than permitted by the welding machine's efficiency. Make
sure that wire speed/current and voltage are set correctly.
Fault symbols
The indicator flashes when other types of errors occur. At the
same time an error code is shown in the display.
Selected error codes
Mains supply fault
The indicator is displayed, when the mains
voltage is too high.
Connect the welding machine to 400V AC, +/-15% 50-60Hz.
Torch cooling fault
Cooling fault is indicated on machines in case of
insufficiant circulation of the cooling liquid due to faulty connection,
defective parts or choking.
Check that the cooling hoses are correctly connected, top up the
water tank and check welding hose and branches.
The cooling fault is cancelled by pressing shortly on the
Gas control fault (IGC)
Gas fault exists due to a to low or high gas flow.
Make sure that the pressure on the gas flow is higher than 2 bar and
less than 6 bar, corresponding to 5 l/min and 27 l/min.
The fault is disconnected by adjusting the manual gas flow to
27 l/min. The gas fault is reset by a short pressure on the
Wire feed fault
or
The indicator is displayed, if the wire feed motor is overloaded.
The wire feed motor or magnet valve may be defective.
Other types of faults
If other fault symbols are shown in the display, the machine shall
be switched off and then on to dispose of the symbol. If the fault
symbol is shown repeatedly, repair of the power source is required.
Contact your distributor with information of the fault.
When separate units are connected, the following error codes can be
displayed:
is displayed when the communication between
the power source and the connected unit(s) is
lost.
is displayed when controlling the motor is not
running properly.
is displayed when the motor is overloaded.
-key pad.
-key pad.