Test Instructions
Chapter 7
Operating Instructions
Safety Light Curtain FGS
Move the test rod (diameter 14 or 30 mm as appropriate)
slowly through the guarded access opening following the
direction of the arrows, as shown in the diagram on the left.
Then check the diagram on the right to make sure there is no
risk that anyone may be able to reach over or under the
danger zone.
Note
During this test procedure, only the red LED should be
illuminated.
7.4 Environmental compatibility
The FGS safety light curtain is designed to have the lowest
possible impact on the environment. It neither emits nor
contains any environmentally damaging substances, and
consumes minimal quantities of energy and resources.
Always consider the environment in everything you do at the
workplace. This also means complying with the following
instructions concerning disposal.
138
8 007 716/KA 06/31-03-00
© SICK AG • Safety Systems • Germany • All rights reserved