Electrical Installation - SICK FGS 300 Instrucciones De Operación

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 51
Chapter 5
5

Electrical installation

Note
134
8 007 716/KA 06/31-03-00
Electrical Installation
Figs. 6 and 7 in the appendix show the connection diagram for
the sender and receiver of the FGS.
Test inputs 3 and 4 of the sender must be linked – only then
can the correct functioning of the device after switch-on be
guaranteed.
The FGS Technical Description provides information concerning
further possibilities.
The individual connections are as follows:
24 V DC
Operating voltage + 24 V
0 V
Signal ground (0 V)
Test
Test-contact connection
Earth connection
OSSD1
Safety output 1
OSSD2
Safety output 2
The test input may only be used to check the connected
switching elements.
© SICK AG • Safety Systems • Germany • All rights reserved