Integer register (4 bytes)
Address Value
8000
Main counter
hex
8002
Secondary counter
hex
8004
Preset 1
hex
8006
Preset 2
hex
8008
Multiplication factor
hex
800A
Division factor
hex
800C
Store set value
hex
Perform set
800E
hex
function
Preset 1 sign
8010
hex
setting
Decimal point
8012
hex
setting
8014
Status
hex
r/o:
Read-only access
r/w:
Read and write access
-/w:
Write access
Page 12 | ENG
Access Description
Writing any value resets the main
r/w
counter.
Writing a value resets the main
r/w
counter and the secondary
counter.
r/w
Preset 1
r/w
Preset 2
-/w
Multiplication factor
-/w
Division factor
Storage of the set value
-/w
(no setting is performed)
Setting
-/w
(writing any value performs the
setting)
Byte 1: Sign value
Byte 2: 0
-/w
Byte 3: 0
Byte 4: 0
Byte 1:decimal places
Byte 2: 0
r/w
Byte 3: 0
Byte 4: 0
Byte 1: bit1: output 1
bit2: output 2
Byte 2: bit1 - bit4: main counter
r/o
bit5 - bit8: secondary
Byte 3: 0
Byte 4: 0
Note
Sign values:
Decimal places:
Output:
Counter status:
counter
1: + values
2: -- values
3: +/- values
0: 0 decimal places
1: 1 decimal place
2: 2 decimal places
3: 3 decimal places
4: 4 decimal places
5: 5 decimal places
1: ON
0: OFF
0: counter status: regular
1 :counter status: overflow
2: counter status: underflow