Cap
DC Sensor
Connector
Install the DC Sensor
CAUTION: Risk of property damage. Ensure that the unit's
wires are not caught between the cap and the valve body.
Hold the cap horizontally with the sensing holes down and align
the DC sensor with the cap.
Slide the DC sensor into the cap until the sensor eyes align with
the holes in the cap. Ensure the sensor wires are not pinched and
the DC sensor connector hangs free.
Slide the wedge clip between the DC sensor and the cap until
snug.
Connect the DC sensor connector to the solenoid connector on the
valve. Ensure that the connector pair is fully seated.
Locate the connector assembly adjacent to the sensor body to
prevent pinching when cap is reinstalled on the valve.
Place the cap on the valve body.
Align the sensor eyes toward the user.
Secure the cap with the setscrew.
Open the control stop valve (refer to the "Control Stop Valve
Operation" section).
Reinstall the stop cap onto the control stop and tighten firmly
with a strap wrench.
Verify that the valve functions.