Clean/Replace The Diaphragm - Kohler K-10958 Guía De Mantenimiento

Ocultar thumbs Ver también para K-10958:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Cap
DC Sensor
Connector
Retaining Nut
Solenoid
Connector
Pin
Diaphragm

Clean/Replace the Diaphragm

CAUTION: Risk of product damage. Ensure that the unit's
wires do not get caught between the cap and the valve body.
Close the control stop valve (refer to the "Control Stop Valve
Operation" section).
NOTE: If the unit has not flushed since the stop valve was closed,
the inlet arm may still be pressurized. Use manual flush button to
release pressure.
Use a 3/32" hex head wrench to remove the setscrew from the
cap.
Remove the cap from the valve body.
Disconnect the DC sensor connector from the solenoid connector
by pulling the connectors apart.
Temporarily store the cap and DC sensor assembly in a safe
place.
Use an adjustable wrench to remove the solenoid.
Remove the diaphragm.
NOTE: Take care not to lose the spring and pin contained within the
solenoid assembly.
Rinse any debris from the diaphragm.
Verify the spring and pin are still in place in the solenoid
assembly.
1061436-5-B
Setscrew
Solenoid
Assembly
Spring
Valve Body
16
O-Ring
Piston
Cover
Piston