Average power used per cycle, kWh
Max nominal sound emission, dBA
Average HVAC load, kcal/hr (Btu/hr)
Number of motors in drive train
Wash/reverse motor power, kW (HP)
Distribution motor power, kW (HP)
High extract motor power, kW (HP)
Wash/reverse speed, Gs (RPM)
Distribution speed, Gs (RPM)
High extract speed, Gs (RPM)
Vibration safety switch installed
Safety switch gap setting, mm (in.)
Steam inlet connection size, mm (in.)
Number of steam inlets
Steam required to raise bath temperature
10°C, kg (10F, lb.)
Average consumption per cycle, kg (bhp)
Total electrical heating capacity, kW
Number of electrical heating elements
Electrical heating element size, kW
Time required to raise bath temperature
10°C, min. (10°F, min.)
F232156
Table 4 (Continued)
Power Consumption
Drive Train Information
Cylinder Speeds/Centrifugal Force Data
Balance Detection
Direct Steam Heating (Optional)
LOW
MED
HIGH
Electrical Heating (Optional)
LOW
MED
HIGH
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation/Operation Supplement
UW35
0.24
72
157 (625)
2
0.3 (0.4)
0.34 (0.45)
2.2 (3)
0.76 / 45
2.10 / 75
133 / 597
N/A
N/A
13 (1/2)
1
1.5 (2.1)
1.7 (2.3)
1.9 (2.7)
21.4 (1.4)
15.6
6
2.6
3.6 (2.4)
4.1 (2.7)
4.7 (3.1)
UW60
0.47
81
220 (875)
2
0.7 (0.9)
0.8 (1.0)
2.6 (3.5)
0.80 / 42
2.04 / 67
139 / 561
STD
0.15 (0.006)
13 (1/2)
1
2.4 (3.3)
2.6 (3.7)
2.9 (4.1)
33.4 (2.1)
25.2
6
4.2
3.7 (2.4)
4.1 (2.7)
4.6 (3.0)
13