SIMPLIFIED INSTRUCTIONS FOR K800-1400-2200 FCE-FCM WITH L1-CRX
1° Connecting the motor and limit switch (done in the factory)
PHOTOCELL 1
PHOTOCELL 2
COMMON
LIMIT SWITCH
LIMIT SWITCH
COMMON
TIMER
PEDESTRIAN
SINGLE COMMAND
CLOSE
OPEN
COMMON
24Vdc 0,4A ±15%
A+TEST / A-
PHOTOCELLS
24Vdc 0,4A ±15%
AUTO-TEST
700 W MAX
R=2,2K 1/4W
LED
COMMON
BLINKER
230Vac 40W MAX
OPEN
COMMON
M
CLOSE
POWER SUPPLY
230Vac 50 Hz
2° Installing and adjusting the limit plate cams
Place the cams on the rack.
Tighten the two screws to lock them. How to finely
adjust cam intervention is explained below.
K FCE
ITA
ESP ENG FRA GRE DEU RUS ARA THAI BUL FAR TUR
COMMON
STOP
ENCODER
EDGE 1
EDGE 2
K FCM
K FCE
TORQUE TRIMMER - Electronic regulator for motor torque
Adjustment of motor torque is carried out using the TORQUE
Trimmer which varies the output voltage to the head/s of the
motor/s (turn clockwise to increase torque).
This torque control is activated after 2 seconds form any
manoeuvre begging, whereas the motor is turned on at full
power to guarantee the starting at the manoeuvre begging.
PAY ATTENTION: IF THE TORQUE TRIMMER SETTING IS
CHANGED, IT IS PREFERABLE TO REPEAT
THE TIME PROGRAMMING.
LOW SPEED TRIMMER - Electronic regulator for low speed
on approach
Adjustment of low speed is carried out using the LOW SPEED
Trimmer which varies the output voltage to the head/s of
the motor/s (turn clockwise to increase speed). Adjustment is
carried out to establish the correct speed at the completion
of opening and closing, depending on the structure of the
gate, or if there is any light friction that could compromise the
correct working of the system.
TCA TRIMMER - AUTOMATIC CLOSING pause time regulator
for TOTAL or PEDESTRIAN openings
default NOT ACTIVATED and LED DL11 OFF (trimmer fully
rotated counterclockwise)
This trimmer makes it possible to adjust the pause time
for total or pedestrian automatic closing. Only with gate
completely open (total) or partially open (pedestrian) and LED
DL11 ON (trimmer rotated clockwise to activate the feauture).
The pause time (for a totally opened gate) can be adjusted
from a minimum of 2 s up to a maximum of 2 minutes.
The pause time (for gate open with PED. control) can be
adjusted from a minimum of 2 seconds to a maximum of 30
seconds.
ANTENNA
433 MHz
ANTENNA
BRAIDING
Release the motor (turn the key counter clockwise until the limit is
reached without forcing) and move the gate by hand
Check when the cams are activated.
Note: The cams must press the electric microswitches before the mobile
part touches the mechanical stops.
HIN