3. Force adjustment and low speed adjustment when approaching
Note: In this phase the gate moves only by constantly pressing the PROG button and is the step-by-step type which means that each time the
PROG button is pressed we have an open-close-open ... manoeuvre.
a) Position the gate halfway.
b) Set the microswitches for K800 DIP 1-2-3-4-5-6-7-8-13-14-15-16 on OFF and DIP 9-10-11-12 on ON.
for K1400 set DIP 14 ON
for K2200 set DIP 15 ON.
c) Set DIP 1 on ON (the DL1 LED flashes quickly)
d) Set the "TORQUE" force adjustment trimmer on minimum
e) Press and hold the PROG button and gradually increase "TORQUE" force, only if necessary (WARNING: too much force can be dangerous for
the users)
f) After 8 seconds the motor slows to a speed that is adjusted with the "LOW SPEED" trimmer.
g) Release the PROG button and press PROG again until the gate is 20 cm from the closing limit switch.
h) Put DIP 1 back on OFF.
4. PROGRAMMING TOTAL OPENING.
NOTE: If the STOP, PHOT 1, PHOT 2, EDGE 1 and EDGE 2 inputs are not connected, make jumpers between COM A + / STOP / PHOT 1 / PHOT 2 / EDGE
1 / EDGE 2 before proceeding with programming.
NB: In this case the Edge, Photocell and Stop button safety devices will be ignored. The LEDs DL6-7-8-9-10 must be on.
1 - IMPORTANT: POSITION THE GATE AT APPROXIMATELY 20 CM FROM THE CLOSING LIMIT SWITCH.
2 - Put the DIP 2 in the ON position => the DL1 LED begins to flash.
3 - Press the PROG./RADIO/OPEN/START button. The gate will begin a series of movements. DO NOT WALK IN FRONT OF THE PHOTOCELLS WHEN
THE GATE IS MOVING. Set up is complete when the gate remains closed and the DL1 LED is off.
4 - Turn the DIP 2 back to the OFF position.
5. PROGRAMMING THE PEDESTRIAN GATEWAY OPENING
With the gate closed:
1 - First set DIP2 to ON (DL1 led flashes quickly) and after DIP1 to ON (DL1 led flashes slowly).
2 - Press the pedestrian button (COM A+/PED.) => M1 opens.
3 - Press the pedestrian button (COM A+/PED.) To stop M1 at the desired point.
4 - Press the pedestrian button (COM A+/PED.) To close M1.
5 - When the closure is reached, reset DIP 1 and 2 to OFF.
6. PROGRAMMING THE REMOTE CONTROL FOR TOTAL OPENING
Programming can be done only when the gate is stationary.
1 - First set DIP 1 to ON and then DIP 2 to ON. The LED DL12 flashes red for 10 seconds.
2 - Press the remote button (usually channel A) within the allotted 10 seconds. If the remote is memorized properly LED DL12 blinks green and a buzzer tone confirms the correct memorization.
The 10 seconds for programming the codes are automatically renewed, with LED DL12 which flashes red, in order to store the next transmitter.
3 - To finish programming, wait 10 seconds, or press the PROG button briefly. LED DL12 stops flashing.
4 - Re-set DIP 1 to OFF and DIP 2 to OFF.
7. Customising configuration
You can change the configuration by moving the various micro-switches
DIP 4
Photocells always active (OFF) - Photocells active only during closing (ON)
DIP 5
Pre-blinking (ON) - Normal blinking (OFF)
DIP 6
Single pulse command (START) and RADIO - step-by-step (ON) - automatic (OFF)
DIP 7
Photocells AUTO-TEST activation (ON-activated).
DIP 8
Encoder management (ON - activated) for PLUS models - with encoder
DIP 9
Slowdown (ON - activated)
DIP 10
Electronic brake (ON-activated)
DIP 11
Gradual start (ON-activated)
DIP 12
Activate the radio system SUN/MOON (ON) - SUN-PRO (OFF)
DIP 13
Contactors management (ON - activated) - NOTE: Even if enabled, DIPs 8-9-10-11 are excluded from their operation
for K800 set DIP 14-15-16 OFF
for K1400 set DIP 15-16 OFF, DIP 14 ON
for K2200 set DIP 14-16 OFF, DIP 15 ON.
IMPORTANT: The system must comply with all the standards and Directives currently in force.
ATTENTION: Install the APP card (or the APP+ card with its modules) and use your smartphone with the RIB GATE App to take advantage of all the advanced features that the L1 control