5 - PROGRAMMING
5.4
System size
Only visible in multiple valve systems and only on the master #1 valve
This parameter shows the number of valves to be connected (2 to 4 valves) in the system.
5.5
Regeneration type
This parameter allows setting the regeneration type.
- Timeclock delayed: The electronics will establish that a regeneration is requested when the set
amount of days in the calendar forcing is reached. The valve will regenerate at a present time.
- Meter delayed: The electronics will establish that a regeneration is requested when the volume
of soft water reaches the reserve capacity. The regeneration will start at a set time.
- Meter immediate: The electronics will establish that a regeneration is requested when the
volume of soft water reaches zero. The regeneration starts immediately.
5.6
Valve type
This parameter allows you to select which valve is being used with the 3200 NXT.
Example:
V A L V E
5.7
Regenerant flow
This parameter allows you to select the direction of flow for the brine to regenerate the resin.
The availability depends on the valve type programmed in the previous step. There are 3 types:
- co-current (by default)
- counter-current
- counter-current dry salt
5.8
Remote controlled regeneration
The valve is controlled by an external device. The regeneration will start immediately after the
closure of the contact which timing is predetermined during the setting. A closure time is
requested to validate the signal before the regeneration start.
This mode can be combined with the other methods of regeneration, it will have priority once it
is activated.
Adjustable from 1 minute to 1h39 min.
33
19/01/10
14:10
Page 33
S Y S T E M
T Y P E
2 9 0 0 / 2 9 1 0
R E G E N E R A T I O N
C O U N T E R - C U R R E N T
R E M O T E
S T A R T : N O
R E M O T E
S T A R T :
S I Z E
:
2
V A L V E S
V A L V E
T Y P E
I N
S I G N A L
Not used
Remote control used,
S I G N A L
and a 1 minute contact
0 0 : 0 1 : 0 0
programmed.
E
N
G
L
I
S
2 8 5 0
H
3200 NXT