3200 NXT EN _P19-35
5 - PROGRAMMING
5.16
Auxiliary relay
This parameter allows you to enable the relay output during regeneration.
The parameter has two settings. The first setting is to activate the output, and the second setting
is to deactivate the output.
Relay output activated at the beginning
of regeneration
A U X
S T A R T :
5.17
Chemical pump
Only visible in systems with a meter
This parameter controls the relay output during the service based upon the volume of treated
water.
It is composed of two displays. The first one is used to determine a volume which will activate
the relay. The second one is used to determine how long the relay has to be activated.
Relay activated every 20 liters
P U M P
V O L U M E :
Note : If both options are use, it is the responsibility of the OEM to supply the required switching
information needed to control the two apparatus connected to the same relay.
5.18
Flow meter selection
This parameter allows the selection of the size for the flow meter
- 1'' paddle
- 1'' turbine
- 1.5'' turbine
- 1.5'' paddle
- 2'' turbine
- 3'' paddle
- Generic meter
5.19
Generic meter
The following parameters are only visible if «generic »was selected in flow meter selection.
The first display is to enter the maximum flow rate of the meter.
The second display is to enter the values for the flow meter.
Adjust the number of liters per pulse.
1 liter per 1 pulse
F O R
35
19/01/10
14:11
Page 35
A U X I L I A R Y
R E L A Y
R E L A Y
R E G E N
0 0 : 0 0 : 0 0
C H E M I C A L
E N . F R E Q U .
0 0 2 0
F L O W
P E A K
+
0 0 1
L I T E R
0 0 1
P U L S E
+
F O R
D I S A B L E D
Relay output deactivated 10 min. after the start
A U X
R E L A Y
E N D :
P U M P
D I S A B L E D
P U M P
O P E R A T I N G
L
T I M E
:
M E T E R
2 . 0 " P A D D L E
F L O W
0 2 9 0
l p m
+
0 0 5
F O R
0 0 1
L I T E R S
0 1 0
P U L S E
of regeneration.
R E G E N
0 0 : 1 0 : 0 0
Relay activated for 1 minute
0 0 : 0 1 : 0 0
5 liters per 1 pulse
L I T E R
0 0 1
P U L S E
1 liter per 10 pulses