3) Connect to the pipeflex (3/8") output from the machine the treatment system for water intended for
human consumption (or drinking) (only use pipes suitable to contact with water intended for human
consumption according to the law in force in the country where the product is used). Remove the front
tray and connect the outlet pipe by fixing it to the plastic tray (drainage). Switch on the water purifier
and check for any leaks. (Observe the rules issued by the relevant authorities for each state,
region or county). For optimal use of the appliance, check that the water supply pressure exceeds
1 bar (100 kPa) and be less than 6 bar (600 kPa). If the incoming water pressure exceeds 6 bar, we
recommend to use a pressure reducer.
4) Before start-up the fitter must make sure the machine has been properly connected to the electrical
and earthing systems involved and check the efficiency of protection from direct contact.
In Europe connect the approved cord H05VV-F 3G 1.5 mm with the Schuko plug to the electricity
supply.
In USA-Canada connect the approved cord Type SJTO, rated 3x14 AWG, 300 V, 105°C with the
NEMA 5x15P plug to the electricity supply. IT IS STRICTLY FORBIDDEN TO USE THE MA-
CHINE WITHOUT EFFECTIVE SAFE EARTHING.
4c. Equipment with 7 Liters Boiler, with water supply connection
If your machine is to be connected to the mains water supply call a specialized techni-
cian.
3) Connect the treatment system for water intended for human consumption (or drinking) to the
external motor-pump through pipeflex (3/8"). Then connect the motor-pump to the pipeflex output
from the machine (only use pipes suitable to contact with water intended for human consumption
according to the law in force in the country where the product is used). Remove the front tray and
connect the outlet pipe by fixing it to the plastic tray (drainage). Switch on the water purifier and check
for any leaks. (Observe the rules issued by the relevant authorities for each state, region
or county). For optimal use of the appliance, check that the water supply pressure exceeds 1 bar (100
kPa) and be less than 6 bar (600 kPa). If the incoming water pressure exceeds 6 bar, we recommend
to use a pressure reducer.
NB: In case that the equipment of internal motor pump provided is, connect to the pipeflex (3/8")
output from the machine the treatment system for water intended for human consumption (or drinking).
4) Electrical installation of the machine must be carried out exclusively by qualified personnel,
according to the instructions in this manual and the standards in force in the country of installation.
The machine comes with a suitably tested 2.5 m long H07RN-F 5x2.5 mm
the fitter must connect an EN 60309 approved 3P+N+PE 16A - 400V industrial plug (not provided).
Another type of power lead could be provided if required by the customer or local standards.
As an alternative the fitter may connect the power lead to an omnipole circuit breaker with character-
istics suitable for the electrical system involved, the standards in force in the country of installation and
IEC 60364-1. Before start-up the fitter must make sure the machine has been properly connected to
the electrical and earthing systems involved and check the efficiency of protection from direct contact,
as per IEC 60364-1. IT IS STRICTLY FORBIDDEN TO USE THE MACHINE WITHOUT
EFFECTIVE SAFE EARTHING.
5. MACHINE IGNITION, SELECTOR 0,1
1) Rotate the switch knob to position 1. The red indicator light comes on.
2) When the machine is switched on, the electronic card checks water level inside the boiler. After
approx. 3 seconds, the filling pump and solenoid valve are enabled for filling.
3) In position 1 the coffee machine will automatically be filled with water up to the pre-set level (level
probe inside the boiler).