2.1 Intended Purpose
This device shall only be operated as a built-in
device. Its fields of application are industrial
processes and controls for manufacturing lines in
the metal, wood, plastic, paper, glass and textile
industry, and similar applications.
Overvoltages at the screw terminals of the device
must be limited at the values of the overvoltage
category II.
If the device is used for monitoring machines or
process flows, in which a breakdown of the device
or an operating mistake might lead to machine
damages or operator accidents, the user must take
suitable safety measures.
3. Start-up
After powering the device, the following message is
displayed for 2 seconds:
Then the device type is displayed for
2 seconds, followed by the software version,
also for
2 seconds. After reading the EEPROM,
the device switches to the operating mode.
3.1. Reset, Back to Factory Setting
Press both keys simultaneously and power the
device: the following message appears on the
display:
The device is reset to the factory settings and is
now ready for operation.
EN - Page 4
3.2. Programming and Operation of the Setpoint
Generator With the 2 Keys
⇑
⇑
While programming, press both keys simultaneous-
ly to switch over to the following parameter.
Within a parameter, confirm an input also by pres-
sing both keys.
⇑
The right key allows selecting the values of the
parameters. To input a numerical value, select the
decade with the left key
⇑
and select a value between 0 ... 9
⇑
with the right key.