The Auto Operating Mode - Kübler CODIX 533 Manual Del Usuario

Generador de valores de consigna
Ocultar thumbs Ver también para CODIX 533:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

4.2.3 The Auto Operating Mode

1. The following parameters can be programmed
for the Auto mode:
1 sec
EN - Page 8
A
see 4.2.3.1
to
to
to
to
to
to
2. Functions
SPecial display function, see 4.2.3.1
SiGnal allows selecting the setpoint
output in volts or mA.
time allows selecting the time unit in
seconds or minutes.
Number of PEriods allows defining
the number of reference points.
output 1 allows selecting the current
or voltage value for the first reference point.
PEriod. 1 allows defining the duration
of the first period.
(A maximum of 20 periods may be programmed)
The maximum setpoints ou. X and the times PE.
X result from the setting of PEr.
The function cYcle allows defining
the number of cycles to be carried out.
If cYcle = 0,
matically after 1 second. noCYcle will start an
endless loop.
Press both keys simultaneously to switch over to
the following parameter. Within a parameter, select
the decade with the left key and select a value
from 0 ... 9 with the right key.
3. After setting the value of cYcl, press both keys
simultaneously; the following message is dis-
played:
4. Use the right key to select YES or no
5. If YES is selected, press both keys simulta-
neously to end the programming
A
to
bei mA 24.00
to
bei mA 24.00
to
is displayed auto-

Publicidad

Tabla de contenido
loading