10 Troubleshooting
Fault
Cause
• Contact tip loose
Torch neck gets
• Contact tip loose on the torch and
hot
• Coolant flow too low
• Control lead interrupted/defective
No trigger
• Flow control in the coolant
function
Wire burned
• Wrong parameters set
solid in the
• Contact tip worn out
contact tip
• Spiral liner/PA liner clogged
Irregular wire
• Contact tip and wire diameter not
feed
• Wrong contact pressure set on the
Arc between the
• Spatter bridge between the contact
gas nozzle and
the workpiece
• Contact tip not aligned to the wire
Erratic arc
• Wrong welding parameters set
• Wire guide unit worn out
• Strong weld spatter build-up in the
• Insufficient or no gas coverage
Pore formation
• Air current blows shielding gas
Tab. 13
Troubleshooting
EN - 24
toward the workpiece
recirculator has triggered
aligned
wire feeder
tip and the gas nozzle
diameter or contact tip diameter
enlarged
gas nozzle
away
ROBO Compact W600
Troubleshooting
• Check and tighten
• Check and tighten
• Check the cooling system
• Check/repair
• Check the coolant level and top up if
necessary
• Check and correct setting
• Replace
• Clean both directions with compressed
air or replace if necessary
• Replace contact tip
• Correct as specified by the manufacturer
• Clean and spray the gas nozzle interior
• Check the contact tip
• Correct the welding parameters
• Replace the wire guide
• Clean the gas nozzle
• Check the gas cylinder contents and
pressure setting
• Use partitions to shield the welding area