9.4 Cleaning the cable assembly

WARNING
Risk of injury
Serious injuries can be caused by parts swirling around.
• When cleaning the wire guide with compressed air, always wear personal protective
clothing, in particular safety goggles.
NOTICE
• Replace any damaged, deformed or worn parts.
Figure 8 below is based on cable assembly connectors Euro-ZA and RPC, version Euro-ZA is
shown.
Carry out each step in accordance with the figures below:
Fig. 8
1 Disconnect the cable assembly and lay it down straight.
2 Clean the wire conduit from both sides with compressed air.
3 Remount all parts in the reverse order.