❍Volume (Controller number 7)
Status
2nd byte
BnH
07H
n = MIDI channel number:
0H - FH (ch.1 - ch.16)
vv = Volume:
00H - 7FH (0 - 127)
* Volume messages are used to adjust the volume balance of each part.
❍Pan (Controller number 10)
Status
2nd byte
BnH
0AH
n = MIDI channel number:
0H - FH (ch.1 - ch.16)
vv = pan:
00H - 40H - 7FH (Left - Center - Right)
* In the rhythm part (ch.10), ignored this message.
❍Expression (Controller number 11)
Status
2nd byte
BnH
0BH
n = MIDI channel number:
0H - FH (ch.1 - ch.16)
vv = Expression:
00H - 7FH (0 - 127)
* Expression messages are used to adjust the level of each part.It can be used
independently from volume messages. Expression messages are used for musical
expression within a performance; e.g., crescendo and decrescendo.
❍Hold 1 (Controller number 64)
Status
2nd byte
nH
40H
n = MIDI channel number:
0H - FH (ch.1 - ch.16)
vv = Control value:
00H - 7FH (0 - 127) 0-63 = OFF, 64-127 = ON
* In the rhythm part (ch.10), ignored this message.
❍Effect 1(Reverb Send Level) (Controller number 91)
Status
2nd byte
BnH
5BH
n = MIDI channel number:
0H - FH (ch.1 - ch.16)
vv = Reverb send level:
00H - 7FH (0 - 127)
❍RPN MSB/LSB (Controller number 101, 100)
Status
2nd byte
BnH
65H
BnH
64H
n = MIDI channel number:
0H - FH (ch.1 - ch.16)
mm = upper byte of parameter number specified by RPN (MSB)
ll = lower byte of parameter number specified by RPN (LSB)
* In the rhythm part (ch.10), ignored this message.
* The value specified by RPN will not be reset even by messages such as program change
or reset all controllers.
* Regarding the RPN please refer to p. 200.
On the GM mode of TD-8, RPN can be used to modify the following parameters. Regarding
the value of each parameter, refer to Data Entry (Controller number 6, 38).
RPN
MSB LSB
Parameter
00H 00H
Pitch Bend Sensitivity
00H 01H
Master Fine Tuning
00H 02H
Master Coarse Tuning
7FH 7FH
RPN null
G Program Change
Status
2nd byte
CnH
ppH
nn = MIDI channel number:
0H - 8H, AH - FH (ch.1 - ch.16)
pp = Program number:
00H - 7FH (prog.1 - prog.128)
* The sound will change beginning with the next note-on after the program change is
received. Voices which were already sounding before the program change was received
will not be affected.
3rd byte
vvH
3rd byte
vvH
3rd byte
vvH
3rd byte
vvH
3rd byte
vvH
3rd byte
mmH
llH
G Channel Pressure
Status
2nd byte
DnH
vvH
n = MIDI channel number:
0H - FH (ch.1 - ch.16)
vv = Channel pressure:
00H - 7FH (0 - 127)
* When channel pressure is received, the effect selected for channel pressure, in global
parameter control (p. 206), is applied.
* In the rhythm part (ch.10), ignored this message.
G Pitch Bend Change
Status
2nd byte
EnH
llH
n = MIDI channel number:
0H - FH (ch.1 - ch.16)
mm, ll = Pitch Bend value:
00 00H - 40 00H - 7F 7FH (-8192 - 0 - +8191)
* In the rhythm part (ch.10), ignored this message.
I Channel Mode Messages
G All Sounds Off (Controller number 120)
Status
2nd byte
BnH
78H
n = MIDI channel number:
0H - FH (ch.1 - ch.16)
* When this message is received, all currently-sounding notes on the corresponding
channel will be silenced. However, the status of channel messages will not change.
G Reset All Controllers (Controller number 121)
Status
2nd byte
BnH
79H
n = MIDI channel number:
0H - FH (ch.1 - ch.16)
* When this message is received, the following controllers will be set to their reset values.
Controller
Reset value
Pitch Bend Change
+/-0 (center)
Channel Key Pressure
0 (off)
Modulation
0 (off)
Expression
127 (MAX)
Hold 1
0 (off)
RPN
unset; previously set data will not change
G All Notes Off (Controller number 123)
Status
2nd byte
BnH
7BH
n = MIDI channel number:
0H - FH (ch.1 - ch.16)
* When All Notes Off is received, all notes on the corresponding channel will be turned
off. However if Hold 1 is ON, the sound will be continued until these are turned off.
I System Realtime Message
G Active Sensing
Status
FEH
* When Active Sensing is received, the unit will begin monitoring the intervals of all
further messages. While monitoring, if the interval between messages exceeds about 420
ms, the same processing will be carried out as when All Sounds Off, All Notes Off and
Reset All Controllers are received, and message interval monitoring will be halted.
I System Exclusive Message
* Regarding the system exclusive message refer to p. 201.
The System Exclusive Messages received by the normal mode of TD-8 are; Universal Non-
realtime System Exclusive Messages, Universal realtime System Exclusive Messages, Data
Requests (RQ1), and Data Set (DT1).
Aplicación MIDI
3rd byte
mmH
3rd byte
00H
3rd byte
00H
3rd byte
00H
205