Programming
e. When high water level is reached, the
display stops flashing, the dot above the
second digit from the left lights, and the
display shows "AFIL" while energizing
the "AF" (auxiliary fill) output for five
seconds. Basket rotation continues with
the drain closed.
f. The display will read "SUP1" while
energizing supply 1 output for five
seconds. Basket rotation continues
with the drain closed. The heat output
energizes.
g. The display reads "SUP2" while
energizing supply 2 output for five
seconds. Basket rotation continues
with the drain closed. The heat output
remains on.
h. The display will read "SUP3" while
energizing the supply 3 output for five
seconds. Basket rotation continues
with the drain closed.
i. The display will flash "drAI" and "For"
when the motor is operated at low
speed forward during the drain test. The
display will flash "drAI" and "dISt"
when the motor is operated at
distribution (balancing) speed.
j. When the drain opens, the three dots
above the three right display digits
should go off, indicating that the water
is draining.
k. The computer will attempt to balance
the load up to ten times before aborting
the test cycle.
Case 1: If the load balancing has failed
ten times (test cycle only), the
computer will then turn off all outputs
and flash "FAIL"/"bAL" for several
seconds, indicating that the load failed
26
to balance after ten tries. The computer
will then enter the stop routine.
Case 2: If the machine drained
correctly and the load balanced, the
computer will display "HI 1." The
basket will rotate at low extract spin
speed for 45 seconds.
l. The display will read "HI 2," and the
basket will rotate at high extract spin
speed for 45 seconds.
m. The computer will then turn off all
outputs, and the machine will coast for
about 20 seconds. As the machine
coasts to a stop, the display will read
"SdLY."
Upon completion of the test cycle, the machine
will go through the stop routine. The door will
then unlock, and the test cycle will be disabled.
F232061