Technical Data; General Data; Electrical Data - pizzato HP AA Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 17
Solution with one safety hinge and two
additional hinges
B
A
D
F
max
B
200 min - 1000 max
Fmax (N) = 200,000/D (mm)
7 MARKINGS
The outside of the device is provided with external marking positioned in a visible
place. Marking includes:
- Producer trademark
- Product code
- Batch number and date of manufacture. Example: A21 HP1-123456. The batch's first
letter refers to the month of manufacture (A=January, B=February, etc.). The second
and third letters refer to the year of manufacture (21 = 2021, 22 = 2022, etc.).

8 TECHNICAL DATA

8.1 Housing
Metal housing, powder-coated
Protection degree:
Corrosion resistance in saline mist: > 300 hours in NSS acc. to ISO 9227

8.2 General data

SIL level (SIL CL):
Functional safety ISO 13849-1
Structure of the electrical circuit connected to the device:
- with 1 channel: can be used up to category 1 and PL c;
- with 2 channels controlled by a safety module: can be used up to category 3 and PL
d, only if mechanical faults can be excluded.
It should be noted that the series connection of two or more devices reduces the self-
monitoring capacity of the system, see ISO/TR 24119.
Performance Level (PL):
Safety parameters:
Service life:
Ambient temperature for hinges without cable: -25°C ... +80°C (standard)
Ambient temperature for hinges with cable:
Storage temperature:
Max. operating altitude:
Max. actuation frequency:
Mechanical endurance:
Max. actuation speed:
Min. actuation speed:
Mounting position:

8.3 Electrical data

Rated impulse withstand voltage U
imp
Conditional short circuit current:
Pollution degree:
Ambient temperature
T min / T max
Cable with 2 contacts
std -15°C +60°C
(type E)
+5°C +60°C
Cable with 2 contacts
std -25°C +80°C
(type N)
-5°C +80°C
std
Cable with 2 contacts
-25°C +80°C
(type H)
-40°C +80°C
T6
std
Cable with 2 contacts
-25°C +80°C
(type R)
-40°C +80°C
T6
Cable with 3 contacts
std -25°C +80°C
(type N)
-5°C +80°C
std
Cable with 3 contacts
-25°C +80°C
(type H)
-40°C +80°C
T6
Cable with 4 contacts
std -25°C +80°C
(type N)
-5°C +80°C
Cable with 4 contacts
std
-25°C +80°C
(type R)
-40°C +80°C
T6
std -25°C +80°C
M12 connector, 5-pole
-15°C +80°C
std -25°C +80°C
M12 connector, 8-pole
-15°C +80°C
Legend: (a) = cable, fixed installation; (b) = cable, flexible installation; (c) = cable, mobile
installation; (std) = standard ambient temperature; (T6) = extended ambient temperature.
Legend
Fmax: Force exerted by the weight of
the door (N)
D: Distance from the centre of gravity of
the door to the axis of the hinge (mm)
A: Safety hinge
B: Additional hinge
All values in the drawings are in mm.
IP67 acc. to EN 60529
IP69K acc. to ISO 20653
(Protect electrical cables from direct high
pressure and temperature jets)
Up to SIL 3 acc. to EN 62061*
Up to PL e acc. to EN ISO 13849-1*
* when used with a suitable safety module
B10d: 5,000,000 for NC contacts
20 years
-40°C ... +80°C (T6 extended)
see table
-40°C ... +80°C
2000 m
1200 operating cycles/hour
1 million operating cycles
90°/s
2°/s
any
: 4 kV
1000 A acc. to EN 60947-5-1
3
Thermal
Rated
Protection against
current
insulation
Ith
voltage Ui
(a)
10 A
250 Vac
(b)
(a)
10 A
250 Vac
(b)
(a, b, c)
10 A
250 Vac
(a, b, c)
(a, b)
6 A
250 Vac
(a, b)
(a)
6 A
250 Vac
(b)
(a, b, c)
6 A
250 Vac
(a, b)
(a)
3 A
250 Vac
(b)
(a, b)
4 A
250 Vac
(a, b)
250 Vac
(a)
4 A
300 Vdc
(b, c)
30 Vac
(a)
2 A
36 Vdc
(b, c)
Cable with 2 contacts (type E,
N, H, R)
Cable with 3 contacts (type N, H)
Cable with 4 contacts (type N)
Cable with 4 contacts (type R)
M12 connector, 5-pole
M12 connector, 8-pole
Attention:According to the standard EN 60204-1, versions with 8-pole M12
connector can be used only in SELV/PELV circuits.
Note: the type of cable fitted to the device can be identified by the last letter of the
product code, for example: HP AA050C-2DN
N = PVC cable IEC 60332-1-2 oil-resistant (standard); E = PVC cable IEC 60332-1-2;
H = PUR cable, halogen free; R = railway cable EN 50306-4; M = M12 connector
8.4 Compliance with standards
EN 60947-5-1, EN 60947-1, EN 60204-1, EN ISO 14119, EN ISO 12100, EN 60529,
EN IEC 63000, ISO 20653, UL 508, CSA 22.2 No. 14
8.5 Compliance with directives
Machinery Directive 2006/42/EC, EMC Directive 2014/30/EU, RoHS Directive
2011/65/EU.
9 SPECIAL VERSIONS ON REQUEST
Special versions of the device are available on request.
The special versions may differ substantially from the indications in this instruction
sheet.
The installer must ensure that he has received written information from the support
service regarding installation and use of the special version requested.
10 DISPOSAL
At the end of service life product must be disposed of properly, according to the
rules in force in the country in which the disposal takes place.
11 SUPPORT
The device can be used for safeguarding people's physical safety, therefore in case of
any doubt concerning installation or operation methods, always contact our technical
support service:
Pizzato Elettrica Srl
Via Torino, 1 - 36063 Marostica (VI) - Italy
Telephone +39.0424.470.930
E-mail tech@pizzato.com
www.pizzato.com
Our support service provides assistance in Italian and English
12 EC CONFORMITY DECLARATION
I, the undersigned, as a representative of the following manufacturer:
Pizzato Elettrica s.r.l. , Via Torino, 1 - 36063 Marostica (VI) - Italy
hereby declare that the product is in conformity with whatever prescribed by the
2006/42/EC Machine Directive. The complete version of the present conformity decla-
ration is available on our website www.pizzato.com
Marco Pizzato
DISCLAIMER:
Subject to modifications without prior notice and errors excepted. The data given in this sheet are accurately
checked and refer to typical mass production values. The device descriptions and its applications, the fields
of application, the external control details, as well as information on installation and operation, are provided
to the best of our knowledge. This does not in any way mean that the characteristics described may entail
legal liabilities extending beyond the "General Terms of Sale", as stated in the Pizzato Elettrica general
catalogue. Customers/users are not absolved from the obligation to read and understand our information
and recommendations and pertinent technical standards, before using the products for their own purposes.
Taking into account the great variety of applications and possible connections of the device, the examples
and diagrams given in the present manual are to be considered as merely descriptive; the user is deemed
responsible for checking that the specific application of the device complies with current standards. This
document is a translation of the original instructions. In case of discrepancy between the present sheet and
the original copy, the Italian version shall prevail. All rights to the contents of this publication are reserved in
accordance with current legislation on the protection of intellectual property. The reproduction, publication,
distribution and modification, total or partial, of all or part of the original material contained therein (including,
but not limited to, texts, images, graphics), whether on paper or in electronic form, are expressly prohibited
without written permission from Pizzato Elettrica Srl.
All rights reserved. © 2021 Copyright Pizzato Elettrica
short circuits
(fuse)
10 A 500 V
type gG
10 A 500 V
type gG
10 A 500 V
type gG
6 A 500 V
type gG
6 A 500 V
type gG
6 A 500 V
type gG
3 A 500 V
type gG
4 A 500 V
type gG
4 A 500 V
type gG
2 A 500 V
type gG
8/24
Utilization category DC13
Utilization category AC15
24 V
125 V
250 V
24 V
2 A
0.4 A
0.3 A
4 A
2 A
0.4 A
0.3 A
4 A
2 A
0.4 A
0.3 A
3 A
2 A
0.4 A
0.3 A
4 A
2 A
0.4 A
0.3 A
4 A
2 A
/
/
2 A
120 V
250 V
4 A
4 A
4 A
4 A
3 A
3 A
4 A
4 A
4 A
4 A
/
/

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Hp ab serieHc serie

Tabla de contenido