Descargar Imprimir esta página

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

OWNER'S MANUAL
FLYING INSECT TRAP
MODEL: DT2000XL
Thank you for purchasing the
DYNATRAP
XL flying insect trap!
®
IMPORTANT SAFETY INSTRUCTIONS
WARNING, When using electric appliances, basic precautions should always be followed, including the following:
– To disconnect, turn all controls to the off ("O") position, then remove plug from outlet.
– Unplug from outlet when not in use and before servicing or cleaning.
– To reduce the risk of electrical shock, do not put appliance in water or other liquid.
– This appliance is provided with double insulation. Use only identical replacement parts.
See instructions for Servicing of Double-Insulated Appliances.
– Connect only to a circuit that is protected by a ground-fault circuit-interrupter (GFCI).
INSTRUCTIONS FOR DOUBLE-INSULATED, CORD-CONNECTED APPLIANCES:
In a double-insulated appliance, two systems of insulation are provided instead of grounding. No grounding means is provided
on a double-insulated appliance, nor should a means for grounding be added to the appliance. Servicing of a double-insulated
appliance requires extreme care and knowledge of the system, and should be done only by qualified service personnel.
Replacement parts for a double-insulated appliance must be identical to those parts in the appliance.
IMPORTANT SAFETY INSTRUCTIONS
Please read these instructions before using the DYNATRAP
®
Insect Trap and keep for future reference.
1. Always turn unit off and disconnect plug before servicing, cleaning, or changing bulb.
2. Do not position the unit near heat, gas, oil or other flammable materials.
3. Place product out of reach from children.
4. Never operate this product if it has a damaged cord or plug, if it is not working properly, if it has been dropped or
damaged, or if it has been dropped into water.
5. This product is equipped with 2-conductor cord and 2-prong polarized plug as a safety feature. This plug will fit in a
polarized outlet only one way. If the plug does not fully fit in the outlet, then reverse the plug. If it still does not fit,
then contact a qualified electrician. To reduce the risk of electrical shock, only plug into a properly installed outlet.
Do not attempt to defeat this safety feature.
6. Do not insert fingers or any foreign objects into the unit while it is connected to an electrical outlet.
7. Collected insects within the unit may contribute to fire, so clean insects from the unit frequently.
8. Do not clean this product with water spray. Do not place where it can fall into water, or near flammable materials.
9. Do not touch fan while in motion.
10. Do not abuse cord—never carry or hang unit by cord or yank it to disconnect from receptacle. Keep cord away from heat,
oil, or sharp edges.
11. Extension cords used with this product must be marked with suffix letters "W-A" and with a tag stating "Suitable for Use
with Outdoor Appliances".
12. Use only extension cords that have plug and receptacles that match the product plug. Replace or repair damaged cords.
INSTALLATION
1. Save carton for off-season storage (if needed).
2. If hanging the unit, place it approximately 3–6 feet above floor or ground for optimal catch-rate and easy access for cleaning.
Unit can also be placed on the floor or ground.
3. Plug cord into an outdoor outlet or UL listed extension cord as described in "IMPORTANT SAFETY INSTRUCTIONS".
4. Turn power switch to "ON" position. The switch is located under the upper housing near the light bulbs.
5. For best catch results leave unit on at all times, except when cleaning or servicing.
6. Catch rate activity will be higher at night. For best catch results, place unit away from other competing light sources.
7. It is recommended to place the unit at least 10 to 20 feet away from where people will be sitting.
8. This unit is all-weather resistant – designed for outdoor use including rainy conditions.
CLEANING
Clean the trap at least once a week to prolong life of the unit, insure fire prevention, and provide for more efficient operation.
1. Be sure to clean the unit once per week.
2. For weekly cleaning, remove the retaining cage by twisting clockwise and clean any build up from the inside of the trap with
a brush.
3. When replacing the retaining cage, DO NOT press or push against the screen windows.
REPLACING BULBS
Light bulbs life expectancy is approximately 3,000 hours (or about 4 months), and should be replaced alter that time has passed
in order to maintain optimal UV effectiveness. Even though the bulb's light may be visible to you, it's ability to attract insects
diminishes over time.
1. Turn power switch to "OFF" position, UNPLUG UNIT, and allow bulbs to cool before replacing.
2. Remove plastic cover that fits over the bulbs before removing the old bulbs (a screwdriver is required for this step).
3. Carefully turn bulb counterclockwise and then pull bulb straight out. Note: if you are unable to get the bulb cover off, unscrew
the 3 screws above the metal posts that are supporting the upper housing. Next pull the top part of the unit up, separating it
from the rest of the unit. Proceed to change the bulbs and replace the bulb cover. Place the upper housing back on the posts
and make sure that the housing is placed all the way down on the post. Replace the screws and your unit should be ready.
4. Locate and insert new bulbs into sockets, carefully turn clockwise, and make sure the prongs of the bulb are seated properly.
Replacement bulbs (6-watt fluorescent bulbs – part no. 32050) can be found at your local retailer or can be ordered directly from
by calling 1-877-403-TRAP (8727) or visiting www.dynatrap.com
HOW THE DYNATRAP
XL INSECT TRAP WORKS
®
Flying insects are attracted to the unit by
HOOK FOR
the UV light and the CO
that is generated
2
HANGING
by the photo-catalysis between the UV
(OPTIONAL)
lamps and the TiO
coating. The fan
2
2 UV LAMPS
pulls the insects into the retaining cage,
trapping them until they dehydrate and
die. The screened base can be removed,
so you can periodically empty the contents
into the trash. The screen allows you to
see what's trapped in the compartment,
ON/OFF SWITCH
alerting you when the retaining cage
POWERFUL
needs to be emptied.
YET qUIET FAN
RETAINING CAGE
TROUBLESHOOTING
Problem:
Possible cause:
Bulbs do not illuminate
1. No electrical power
and fan does not spin.
Bulb illuminates, but fan
1. Shorted fan
does not spin.
Fan spins, but bulb does
1. Bulb not seated
not illuminate
properly
2. Burnt out bulb
LIMITED WARRANTY
warranties to the original purchaser that this product is free from defective materials and
workmanship. This warranty is limited to remedy any defective part for a period of one year from date of
original date of purchase. Retain your original receipt as proof of purchase. This warranty does not apply
to the light bulb, nor to, in our judgment, misuse or abuse. If this unit has been altered, no warranty is in
force. This warranty does not apply if this unit is purchased outside the United States, Canada and Mexico.
In no case shall
be liable for any accidental, punitive, consequential, or any other damages
of any kind for breach of this or any other warranty, expressed or implied, whatsoever. Some states do
not allow limitation on how long an implied warranty lasts, so the above limitation or exclusion may not
apply to you. This warranty gives you specific legal rights, and you may also have other rights that vary
from state to state.
PARTS & ACCESSORIES AVAILABLE
PART
DESCRIPTION
32050
6-Watt Replacement Fluorescent Bulbs (2 pieces)
32065
Damper Flaps
Dynamic Solutions Worldwide, LLC
12247 W. Fairview Ave. Milwaukee, WI 53226
PROTECTIVE SCREEN
Phone: 414-431-2819
Toll free: 1-877-403-TRAP (8727)
Toll free fax: 877-403-3293
Email: dynatrapinfo@dsw-llc.com
Visit us online at www.dynatrap.com
© Dynamic Solutions Worldwide, LLC
TIO
COATED SURFACE
2
AUTOMATIC DAMPER
CLOSES WHEN TURNED
OFF PREVENTING
LIVE MOSqUITOS FROM
SAVE THESE INSTRUCTIONS
ESCAPING.
Correction:
1. Check plug and receptacle and fuse or circuit breaker.
2. Check to make sure power is switched to the "ON"
position.
1. UNPLUG UNIT: Examine fan to see that it is free from
foreign material, dirt or build-up of dead insects. Clean unit as
in "CLEANING" section.
1. Check all sockets for proper bulb seating and alignment.
2. Replace bulb if needed following instructions under
"Replacing Bulbs".

Publicidad

loading

Resumen de contenidos para DynaTrap XL DT2000XL

  • Página 1 Flying insects are attracted to the unit by HOOK FOR the UV light and the CO that is generated Please read these instructions before using the DYNATRAP ® Insect Trap and keep for future reference. HANGING by the photo-catalysis between the UV (OPTIONAL) 1.
  • Página 2 4. Inserte los focos nuevos en los sockets, y cuidadosamente gire hacia la derecha, asegúrandose que los las terminales del foco INSTRUCCIONES IMPORTANTES DE SEGURIDAD son colocados correctamente. Sírvase leer estas instrucciones antes de usar el trampa electrónico de insectos DYNATRAP ® y guárdelas como Los focos de repuesto (6 vatios fluorescentes –...