Descargar Imprimir esta página

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

DT250IN
OWNER'S MANUAL
FLYING INSECT TRAP
Thank you for purchasing
the DYNATRAP
®
flying insect trap!
This product may be covered by one or more U.S. patents
or pending patent applications. See www.DynaTrap.com/patents
IMPORTANT: READ CAREFULLY
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS
WARNING:
when using electric appliances, basic precautions
should always be followed, including the following:
1. Please read all instructions before using the DynaTrap
Insect Trap and keep for future reference.
®
2. To disconnect, twist housing to the 'OFF' position, then remove plug from outlet.
3. To reduce the risk of injury from moving parts or electric shock, always turn unit off and disconnect plug when
not in use and before servicing or cleaning.
4. Always unplug before replacing lamp. Replace with same type rated 7-Watt bulbs, DynaTrap
5. Do not position the unit near heat, gas, oil or other flammable materials.
6. To reduce the risk of injury, close supervision is necessary when an appliance is used near children.
7. To reduce the risk of electrical shock, do not put appliance in water or other liquid.
Do not place or store appliance where it can fall or be pulled into a tub or sink.
8. Never operate this product if it has a damaged cord or plug, if it is not working properly, if it has been
dropped or damaged, or if it has been dropped into water or other liquid. Return appliance to the nearest
authorized service facility for examination, repair, or electrical or mechanical adjustment.
9. Connect only to a circuit that is protected by a ground-fault circuit-interrupter (GFCI).
10. Do not insert fingers or any foreign objects into the unit while it is connected to an electrical outlet.
11. Collected insects within the unit may contribute to fire, so clean insects from the unit frequently.
12. Do not clean this product with water spray. Do not place where it can fall into water, or near flammable materials.
13. Do not touch fan while in motion.
14. Do not abuse cord—never carry or hang unit by cord or yank it to disconnect from receptacle.
Keep cord away from sharp edges.
15. Use only extension cords that have plug and receptacles that match the product plug. Replace or
repair damaged cords.
16. Only use attachments recommended or sold by the manufacturer.
17. This appliance is provided with double insulation. Use only identical replacement parts.
See instructions for Servicing of Double-Insulated Appliances.
INSTALLATION & OPERATING INSTRUCTIONS
1. Unpack unit.
2. Plug cord into an outlet.
3. Hold the Power switch on the side of the revolving rotation door. Twist the unit
to the "Power ON" position. When you hear a "click", the machine is turned on.
4. For best catch results leave unit on at all times, except when cleaning or servicing.
5. Catch rate activity will be higher at night. For best catch results it is
recommended to keep the unit away from competing light sources.
Intended for household, indoor use only.
6. To reduce the risk of electric shock, this appliance has a polarized plug (one blade
is wider than the other). This plug will fit in a polarized outlet only one way. If the
plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a
qualified electrician to install the proper outlet. Do not change the plug in any way.
9. SERVICING OF DOUBLE-INSULATED APPLIANCES - In a double-insulated appliance,
two systems of insulation are provided instead of grounding. No grounding means is
provided on a double-insulated appliance, nor should a means for grounding be added to the appliance. Servicing of a
double-insulated appliance requires extreme care and knowledge of the system and should be done only by qualified
service personnel. Replacement parts for a double-insulated appliance must be identical to those parts in the appliance.
The symbol must be identical to those parts in the appliance. A double-insulated appliance is marked with the words
"DOUBLE INSULATION", "DOUBLE-INSULATED" or the symbol:
USER MAINTENANCE INSTRUCTIONS - CLEANING
FOR INDOOR USE
Frequent cleaning will prolong the life of the unit, ensure fire prevention and provide for more efficient operation.
1. Be sure to clean the unit once per week
2. To clean, hold the switch on the revolving rotation door and turn it to the "POWER OFF" position.
After hearing the "click", the machine is turned off. Unplug the unit.
3. For weekly cleaning, twist the cage clockwise. Remove any buildup from the inside of the retaining cage and fan with a
brush (included).
4 For major cleaning, remove the four screws securing the fan housing to the light housing. After removing the screws,
gently pull the fan housing away from the light housing. Using a soft brush, remove dirt and debris from the light
housing. Once the cleaning process has been completed, align the screw holes in the fan housing with the screw holes in
the lighting unit and tighten the screws to the base of the lighting unit.
5. When replacing the retaining cage – DO NOT press/push against the screen windows.
REPLACING BULB Replace With DynaTrap Bulb #41050 (or equivalent G24 Type - 56V/7W Bulb)
The light bulb life expectancy is approximately 3,000 hours (or about 4 months), and should be replaced regularly to ensure
optimal UV effectiveness. Even though the bulb's light may be visible to you, its ability to attract insects diminishes over time.
1. Turn power switch to "off" position. UNPLUG UNIT, and allow bulb to cool before replacing.
2. Twist the cage clockwise. Turn the unit upside down.
3. Remove the four screws securing the fan housing to the light housing. After removing the screws, gently pull the fan
model 41050.
®
housing away from the light housing. Using a soft brush, remove dirt and debris from the light housing. Once the clean
ing process has been completed, untighten the screw securing the base of the light bulb to the light housing. Slide the
metal bracket to the side. Cover the bulb with a cloth to protect your finger and hand. Grasp the bulb (with your hand
and fingers protected by the cloth) and gently pull the bulb from the socket.
4. Remove any debris from the lamp socket with a brush before inserting the new bulb. Replace the metal plate over the
base of the bulb and tighten the retaining screw.
5. Align the screw holes in the fan housing with the screw holes
in the lighting unit and
tighten the screws to the base of the lighting unit.
6. Replace the retaining cage at the bottom of the unit.
Replacement fluorescent bulbs can be found at your local
retailer or can be ordered directly from DynaTrap by calling
1-877-403-TRAP (8727) or visiting www.DynaTrap.com
HOW THE DYNATRAP
INSECT TRAP WORKS
®
Flying insects are attracted to the unit by the UV light and CO2
that is generated by the photo-catalysis between the UV lamps
and the special TiO2 coating. The fan then pulls the insects into
the screened base, trapping them until they dehydrate and die.
The base can be removed, allowing the contents to be periodically
emptied into the trash. Monitor the insects trapped in the
retaining cage, through the see-through screen, and empty when
compartment becomes full.
TROUBLESHOOTING
TiO
COATED
2
SURFACE
Problem:
Bulb does not illuminate
and fan does not spin.
Bulb illuminates, but fan
does not spin.
Fan spins, but bulb does
RETAINING
not illuminate.
LIMITED WARRANTY
DYNAMIC guarantees to the original purchaser that this product is free from defective materials and workmanship. This
warranty is limited to remedy any defective part for a period of one year from date of original date of purchase. Retain
your original receipt as proof of purchase. This warranty does not apply to the light bulb, nor to, in our judgment, misuse or
abuse. If this unit has been altered, no warranty is in force. This warranty does not apply if this unit is purchased outside the
United States, excluding Canada and Mexico. In no case shall DYNAMIC be liable for any accidental, punitive, consequential,
or any other damages of any kind for breach of this or any other warranty, expressed or implied, whatsoever. Some states
do not allow limitation on how long an implied warranty lasts, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
REPLACEMENT PARTS
41050
To see all replacement and accessory parts available for your DynaTrap,
including UV-bulbs, fans, retaining cages, and more, visit www.DynaTrap.com.
SAVE THESE INSTRUCTIONS
CUBIERTA
TiO
COATED
2
DE TiO
SURFACE
UV BULB
Dynamic Solutions Worldwide, LLC
VENTILADOR
FAN
12247 W. Fairview Ave.
Milwaukee, WI 53226
RETAINING
CÁMARA DE
1-877-403-TRAP (8727)
CAGE
RECOLECCIÓN
customercare@dsw-llc.com
www.DynaTrap.com
©2020 Dynamic Solutions Worldwide, LLC
CUBIERTA
DE TiO
2
UV BULB
Possible cause:
Correction:
1. No electrical power.
1. Check plug, receptacle, and fuse or circuit breaker.
2. Check to make sure power is switched to the "ON" position.
1. Shorted fan.
UNPLUG UNIT: Examine fan to see that it is free from
foreign material, dirt or build-up of dead insects.
Clean unit as in "CLEANING" section.
VENTILADOR
FAN
1. Bulb not seated
1. Check all sockets for proper bulb seating and alignment.
CÁMARA DE
CAGE
properly
2. Replace bulb, if needed, following instructions under
RECOLECCIÓN
2. Burnt out bulb.
"Replacing Bulb".
7-Watt Replacement UV Fluorescent Bulb (1 piece)
2
LÁMPARA
DE UV
This device complies with Performance Standards
for Light-Emitting Products, 21 CFR, Part 1040,
Chapter 1, Subchapter J, Radiological health.
LÁMPARA
DE UV

Publicidad

loading

Resumen de contenidos para DynaTrap DT250IN

  • Página 1 5. When replacing the retaining cage – DO NOT press/push against the screen windows. REPLACING BULB Replace With DynaTrap Bulb #41050 (or equivalent G24 Type - 56V/7W Bulb) The light bulb life expectancy is approximately 3,000 hours (or about 4 months), and should be replaced regularly to ensure 1.
  • Página 2 REEMPLAZO DEL FOCO Reemplazar con DynaTrap Bulb # 41050 (o equivalente G24 Tipo - 120V / 7W Bulbo UVA) 4. Desenchufe siempre antes de reemplazar la lámpara. Reemplace con el mismo tipo de bombillas de Ta vida de uso de los focos es de aproximadamente 3,000 horas (o cerca de 4 meses), y deben de reemplazarse después de...