Descargar Imprimir esta página

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

DT2000XL
OWNER'S MANUAL
FLYING INSECT TRAP
Thank you for purchasing
the DYNATRAP
®
Insect Trap!
This product may be covered by one or more U.S. patents
or pending patent applications. See www.DynaTrap.com/patents
IMPORTANT, RETAIN
FOR FUTURE REFERENCE:
READ CAREFULLY
IMPORTANT SAFETY INSTRUCTIONS
DAMPER FLAP
WARNING: When using electric appliances, basic precautions should always be followed, including the following:
ALIGNING
ASSEMBLY
NOTCHES (6)
– To disconnect, turn all controls to the off ("O") position, then remove plug from outlet.
– Unplug from outlet when not in use and before servicing or cleaning.
– To reduce the risk of electrical shock, do not put appliance in water or other liquid.
– This appliance is provided with double insulation. Use only identical replacement parts.
CAUTION: To reduce the risk of injury from moving parts, unplug before servicing.
WARNING: Risk of Electric Shock.
See instructions for SERVICING OF DOUBLE-INSULATED APPLIANCES.
Please read these instructions before using the DynaTrap
®
Insect Trap and keep for future reference.
1. Always turn unit off and disconnect plug before servicing, cleaning, or replacing bulb.
2. Do not position the unit near heat, gas, oil or other flammable materials.
3. Mount out of reach from children.
4. Never operate this product if it has a damaged cord or plug, if it is not working properly, if it has been dropped or
damaged, or if it has been dropped into water.
5. The electrical adapter provided with this product is equipped with a 2-conductor cord and a 2-prong.
If the plug does not fully fit in the outlet, contact a qualified electrician. To reduce the risk of electrical shock,
only plug into a properly installed outlet. Do not attempt to defeat this safety feature.
6. Do not insert fingers or any foreign objects into the unit while it is connected to an electrical outlet.
7. Collected insects within the unit may contribute to fire, so clean insects from the unit frequently.
8. Do not clean this product with water spray. Do not place where it can fall into water, or near flammable materials.
9. Do not touch fan while in motion.
10. Do not abuse cord—never carry or hang unit by cord or yank it to disconnect from receptacle.
Keep cord away from sharp edges.
11. If using outdoors, use only extension cords with a tag stating "Suitable for Use with Outdoor Appliances".
12. Use only extension cords that have plug and receptacles that match the product plug.
Replace or repair damaged cords.
13. Only use attachments recommended or sold by the manufacturer.
14. Replace bulb with same type wattage.
15. SERVICING OF DOUBLE-INSULATED APPLIANCES - In a double-insulated appliance, two systems of insulation
are provided instead of grounding. No grounding means is provided on a double insulated appliance, nor should
a means for grounding be added to the appliance. Servicing of a double-insulated appliance requires extreme
2 UV LAMPS
LOOP FOR HANGING
care and knowledge of the system, and should be done only by qualified service personnel. Replacement parts
(OPTIONAL)
for a double-insulated appliance must be identical to those parts in the appliance. A double-insulated appliance is
ON/OFF
SWITCH
marked with the words "DOUBLE INSULATION", "DOUBLE INSULATED" or the
INSTALLATION & OPERATING INSTRUCTIONS
1. Unpack unit. Save carton for off-season storage (if needed).
3. Place the trap on the retaining cage and twist clockwise to the lock position.
4. If hanging the unit, place it approximately 3–6 feet above floor or ground for optimal catch-rate and easy access for
cleaning. Unit can also be placed on the floor or ground.
5. Plug cord into an outdoor outlet extension cord as described in "IMPORTANT SAFETY INSTRUCTIONS".
6. Turn power switch to "ON" position. The switch is located under the upper housing near the light bulbs.
7. For best catch results leave unit on at all times, except when cleaning or servicing.
8. Catch rate activity will be higher at night. For best catch results, place unit away from other competing light sources.
9. It is recommended to place the unit 20 to 40 feet away from where people will be sitting.
10. This unit is all-weather resistant – designed for outdoor use including rainy conditions.
11. To reduce the risk of electric shock, this appliance has a polarized plug (one blade is wider than the other). This plug will fit
in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a
qualified electrician to install the proper outlet. Do not change the plug in any way.
CLEANING
Frequent cleaning will prolong the life of the unit, ensure fire prevention and provide for more efficient operation.
1. Turn power switch to "OFF" position. UNPLUG UNIT.
2. For weekly cleaning, remove the retaining cage by holding the trap securely and twisting counter clockwise. Use the included
cleaning brush to remove any debris from the damper flaps, fan guard and retaining cage. Empty and dispose of contents
in retaining cage.
For major cleaning, remove the six (6) screws
3.
from the unit. Remove the six (6) screws securing the fan guard and damper flap housing
Brush away debris from the inside of the trap, fan guard and damper flaps.
cage.
After cleaning, return fan guard and damper flap housing, align screw holes and secure with screws.
Align screw holes on damper flap assembly to alighing notches and secure with screws. Re-attach retaining cage.
IMPORTANT: DO NOT press or push against the screen windows while cleaning or assembling.
DAMPER FLAP
ALIGNING
ALIGNING
MUESCAS PARA
ENSAMBLAJE DE LA
ASSEMBLY
ALIGNING
NOTCHES (6)
NOTCHES (6)
FAN GUARDIA
ALINEACIÓN (6)
COMPUERTA DE AIRE
NOTCHES (6)
REPLACING BULB REPLACE WITH DYNATRAP BULBS #32050 (or equivalent T5 Type - 120V/6W UVA Bulbs)
The light bulbs life expectancy is approximately 3,000 hours (or about 4 months), and should be replaced regularly to ensure
optimal UV effectiveness. Even though the bulb's light may be visible to you, its ability to attract insects diminishes over time.
1. Turn power switch to "OFF" position. UNPLUG UNIT and allow bulbs to cool before replacing.
2. Remove screw from clear plastic light socket cover (A).
3. Remove the clear plastic light socket cover (B).
4. Carefully turn bulbs counterclockwise and then pull each bulb straight out (C).
5. Locate and insert new bulbs into sockets, carefully turn clockwise, and make sure the prongs of the bulb are seated properly.
6. Replace clear plastic light socket covers and secure with screw.
2 FOCOS
GANCHO PARA COLGAR
ULTRAVIOLETA
(OPCIONAL)
INTERRUPTOR
PARA PRENDER
2 UV LAMPS
symbol.
O APAGAR
ON/OFF
SWITCH
(A)
securing the damper flap assembly and gently lift to separate
(B)
and lift to separate.
Empty and dispose of contents in retaining
DAMPER FLAP
MUESCAS PARA
MUESCAS PARA
ENSAMBLAJE DE LA
DAMPER FLAP
MUESCAS PARA
ENSAMBLAJE DE LA
DAMPER FLAP
ALINEACIÓN (6)
ASSEMBLY
ALINEACIÓN (6)
COMPUERTA DE AIRE
DAMPER FLAP
FAN GUARD
ASSEMBLY
ALOJAMIENTO
ALINEACIÓN (6)
COMPUERTA DE AIRE
HOUSING
LOOP FOR HANGING
2 FOCOS
(OPTIONAL)
ULTRAVIOLETA
INTERRUPTOR
PARA PRENDER
O APAGAR
HOW THE DYNATRAP
®
2 UV LAMPS
INSECT TRAP WORKS
Flying insects are attracted to the unit by the
ON/OFF
SWITCH
UV light and CO2 that is generated by the
photo-catalysis between the UV lamps and the
special TiO2 coating. The fan then pulls the insects
into the screened base, trapping them until they
dehydrate and die. The base can be removed,
POWERFUL
YET QUIET FAN
allowing the contents to be periodically emptied
into the trash. Monitor the insects trapped in the
retaining cage, through the see-through screen,
and empty when compartment becomes full.
RETAINING
CAGE
TROUBLESHOOTING
Problem:
Possible cause:
Correction:
Bulbs do not illuminate and
No electrical power.
1. Check plug, receptacle, and fuse or circuit breaker.
fan does not spin.
Bulbs illuminate, but fan
Shorted fan.
1. UNPLUG UNIT: Examine fan to see that it is free from
does not spin.
foreign material, dirt or build-up of dead insects.
2. Clean unit as in "CLEANING" section.
DAMPER FLAP
ENSAMBLAJE DE LA
Fan spins, but bulbs do not
1. Bulbs not seated properly
1. Check all sockets for proper bulb seating and alignment.
FAN GUARDIA
FAN GUARDIA
DAMPER FLAP
COMPUERTA DE AIRE
ALOJAMIENTO
illuminate.
2. Burnt out bulbs
2. Replace bulbs if needed following instructions under
FAN GUARDIA
FAN GUARD
ALOJAMIENTO
"Replacing Bulb"
LIMITED WARRANTY
DYNAMIC guarantees to the original purchaser that this product is free from defective materials and workmanship. This
warranty is limited to remedy any defective part for a period of one year from date of original date of purchase. Retain
your original receipt as proof of purchase. This warranty does not apply to the light bulb, nor to, in our judgment, misuse or
abuse. If this unit has been altered, no warranty is in force. This warranty does not apply if this unit is purchased outside the
United States, excluding Canada and Mexico. In no case shall DYNAMIC be liable for any accidental, punitive, consequential,
or any other damages of any kind for breach of this or any other warranty, expressed or implied, whatsoever. Some states
do not allow limitation on how long an implied warranty lasts, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.
REPLACEMENT PARTS
32050
2, 6-Watt UV Replacement Bulbs
To see all replacement and accessory parts available for your DynaTrap, including UV-bulbs, fans,
retaining cages, and more, visit www.DynaTrap.com.
SAVE THESE INSTRUCTIONS
Dynamic Solutions Worldwide, LLC
69 N. Locust St., Lititz, PA 17543
1-877-403-8727 (TRAP)
dynatrap@woodstream.freshdesk.com
www.dynatrap.com
This device complies with Performance Standards
for Light-Emitting Products, 21 DFR, Part 1040,
GANCHO PARA COLGAR
(OPCIONAL)
©2020 Dynamic Solutions Worldwide, LLC
Chapter 1, Subchapter J, Radiological health.
LOOP FOR HANGING
(OPTIONAL)
TIO
COATED
2
SURFACE
AUTOMATIC
DAMPER
CLOSES WHEN
TURNED OFF
PREVENTING
LIVE INSECTS
FROM ESCAPING
DAMPER FLAP
D
FAN GUARD
FAN G
DAMPER FLAP
ALOJAMIENTO
HOUSING
5013602

Publicidad

loading

Resumen de contenidos para DynaTrap DT2000XL

  • Página 1 32050 2, 6-Watt UV Replacement Bulbs REPLACING BULB REPLACE WITH DYNATRAP BULBS #32050 (or equivalent T5 Type - 120V/6W UVA Bulbs) 5. The electrical adapter provided with this product is equipped with a 2-conductor cord and a 2-prong. To see all replacement and accessory parts available for your DynaTrap, including UV-bulbs, fans, The light bulbs life expectancy is approximately 3,000 hours (or about 4 months), and should be replaced regularly to ensure If the plug does not fully fit in the outlet, contact a qualified electrician.
  • Página 2 Para ver todas las piezas de repuesto y accesorios disponibles para su DynaTrap, incluyendo REEMPLAZO DEL FOCO Reemplazar con DynaTrap Bulb # 32050 (o equivalente T5 Tipo - 120 V~ / 6 W Bulbo UVA) 6. Cuando la unidad esté conectada a un tomacorriente, NO introduzca los dedos u otros objetos extraños.