• Lithium charging curve :
The GYSflash 20.12/24 PL features a 8 step charging curve designed to ensure optimal charging of LFP batteries.
1
U
I
Analysis
< 1s
CHARGE
OK
1
Step
: Analysis
Analyses the battery state (charge level, polarity inversion, wrong battery...)
2
Step
: Recovery (
Recovering damaged elements due to a prolonged deep discharge.
3
Step
: Charge (
Maximum current fast charge to reach 90% charge level.
4
Step
: Absorption (
Constant voltage charge to reach 98% charge level.
• Estimated charge time :
Charging current
15
Battery capacity
Ah
Charge timing
0% >>> 90%
2 h
• Protections :
GYSFLASH 20.12/24 PL as comprehensive safety features to protect it against short-circuits and polarity reversals. It
has an anti-spark feature which prevents sparks whilst connecting the device to the battery. This charger has double
insulation and is safe to use with the battery in situ as it will protect the vehicle's on-board electronics.
GYSFLASH 20.12/24 PL s fitted with an integrated temperature sensor that ensures that the charging current is adapted to the
ambient temperature to prevent internal the electronics from overheating.
12
GYSFLASH 20.12/24 PL
2
3
Recovery
Charge
Max 5 min
Max 25 h
0.5 A - 1 A - 2 A /
7 A - 15 A - 20 A /
13.8 V /
27.6 V)
Plomb
240
60
60
90
90
Ah
Ah
Ah
Ah
Ah
(24V)
8 h
4 h
6 h
16 h
5 h
4
5
Equalizing Battery System
Absorption
Test
Supplement
Max 20 h
3 min
Max 10 h
0.5 A - 1 A)
7 A - 15 A)
200
300
7
15
Ah
Ah
Ah
Ah
10 h
15 h
1 h
2 h
6
7
Equalizing /
balancing
Max 2 h
(maintenance cycle every
5
Step
: Test
Charge conservation test.
6
Step
: Supplement
Reduce current charge to reach 100% charge
level.
7
Step
: Equalizing / balancing
(
14.4 V /
28.8 V)
Balancing of battery cells.
8
Step
: Floating charge
(
13.8 V /
27.6 V)
Maintains battery charge level at its maximum
and goes through charge maintenance cycle
every 10 days.
Lithium
240
15
25
100 Ah
Ah
Ah
Ah
(24V)
(24V)
1 h
2 h
7 h
16 h
EN
8
Floating charge
No limit
10 days.)
25
100
200
300
Ah
Ah
Ah
Ah
1h30
7 h
10 h
15 h