Controller Description; Technical Specification - Varian 869-8933 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 15

Controller Description

The dedicated controller is a solid-state frequency
converter which is driven by a single chip micro-
computer and is composed of two PCBs which in-
clude power supply and 3-phase output, analog
and input/output section, microprocessor and digi-
tal section.
The power supply, together with the 3-phase out-
put, converts the single phase AC mains supply
into a 3-phase, low voltage, medium frequency
output which is required to power the pump.
The controller can be operated by a remote host
computer via the serial connection. A Windows-
based software is available (optional).

TECHNICAL SPECIFICATION

Pumping speed (with
inlet screen)
N
:
680 l/s
2
He:
810 l/s
H
:
850 l/s
2
Compression ratio
N
:
>1 x 10
2
He:
5 x 10
H
:
2 x 10
2
Base pressure
< 1 x 10
with recommended
(< 1 x 10
forepump
(According to standard DIN 28 428,
the base pressure is that measured
in a leak-free test dome, 48 hours
after the completion of test dome
bake-out, with a Turbopump fitted
with a ConFlat flange and using the
recommended pre-vacuum pump)
Inlet flange
ISO 160 F
Foreline flange
KF 25
Rotational speed
38000 rpm
Start-up time
< 4 minutes
Recommended
DS 402, TriScroll 300
forepump
Operating position
Any
Operating ambient
+10 °C to +45 °C
temperature
Bakeout temperature
80° C at inlet flange max.
Vibration level
< 0.01 µm at inlet flange
(displacement)
Lubricant
permanent lubrication
Cooling require-
Forced air
ments
9
7
6
-10
mbar
-10
Torr)
Noise level
Power supply:
Input voltage:
Input freq.:
Max input power:
Stand-by power:
Max operating
power:
Protection fuse
Compliance with:
Power cable
Serial communica-
tion (Navigator kit)
Installation category
Pollution degree
Storage temperature
Weight kg (lbs)
Pump:
Controller:
When the TV 801 Navigator Bolted Flange has been
stored at a temperature less than 5°C, wait until the
system has reached the above mentioned tempera-
ture.
53
TECHNICAL INFORMATION
<55 dB(A) at 1 meter
100 - 240 Vac
50 - 60 Hz
600 VA
30 to 35 W
- 450 W with forced air
- 300 W with air
1 x 8 A
UNI EN 292-1
UNI EN 292-2
EN-CENELEC 55011
IEC 1000-4-2 (ex 801-2)
IEC 1000-4-3 (ex 801-3)
IEC 1000-4-4 (ex 801-4)
EN 61010-1 (IEC 1010-1)
EN 1012-2
With European or NEMA plug
3 meters long (optional)
RS232 cable with a 9-pin D type male
connector and a 9-pin D type female
connector, and Navigator software
(optional)
II
2
-20° C to +70° C
27 (59.4)
5.4 (12)
NOTE
87-900-980-01(B)

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Sq 337

Tabla de contenido