Specifications

The SC-500 is available with different power inputs, two modes of mechanical operation and
some options regarding wet grinding. This is described in the different sections later on in this
chapter.
1.1

Electrical specifications

To find the specifications that apply to your machine, check the information plate on the
electrical cabinet door.
Never connect the SC-500 to any other voltage or number of phases than described in this
specification.
The power source must be fused according to "External fuse" in this specification; also
the cables used must be marked and rated in accordance with the fuse used. Fail-
ure to comply with the correct fuses may cause fire or injuries.
Power choice
1
Power
Current
Voltage
Frequency
External fuse
3
Power inlet
4
Table 11 Electrical specifications
All models are CE-marked.
If using a generator see "2.6.2 Using a generator"
1
This refers to different power choices. Note that a SC-500 made for one choice of power must be used
with the particular choice.
2
Standard
Maximum current for the fuses used in the power source (i.e. the distribution box).
3
4
This is the standard inlet used. Machines sold outside of EU will be shipped either with a local standard
inlet or an adapter.
44
400 V 3~
230 V 3~
2
4 kW (5 hp)
4 kW (5 hp)
8.8 A
17.6 A
380 – 400 V 3~
200 – 240 V 3~
50/60 Hz ± 5%
50/60 Hz ± 5%
16 A
25 A
415 V 3P+N+PE
250 V 3P+PE
230 V 1~
4 kW (5 hp)
30 A
200 – 240 V 1~
50/60 Hz ± 5%
30 A
250 V 2P+PE
www.scanmaskin.com