Technical data
Operating voltage
Battery type
Power consumption
Power consumption standby
Flow pressure range
Ambient temperature
Storage temperature
Flow rate at 1 bar with flow limiter
Flush time, factory setting
Flush time, adjustment range
1)
Battery service life: approx. 2 years
Operation
Actuating the flush
The electronic flush actuation has infrared
leg detection. The leg detection range starts
approximately 50 cm in front of the urinal.
1
Enter the detection range and
remain there for at least 10 seconds.
14
1)
Battery operation
3 V DC
Alkaline battery (1.5 V
AA)
< 0.5 W
< 0.1 W
100-800 kPa
1–8 bar
5–40 °C
-20 – +70 °C
0.18 l/s
7 s
1–15 s
2
Leave the detection range.
✓ The flush will actuate.
18014401623384843-1 © 09-2018
Generator operation
6.6 V DC
–
< 0.5 W
< 0.1 W
100-800 kPa
1-8 bar
5–40 °C
-20 – +70 °C
0.18 l/s
7 s
1–15 s
966.934.00.0 (02)