This appliance belongs to construction type classification A1, therefore connection to a flue is not necessary.
The distribution network pressure must meet the following
specifications:
ALLOWED
LPG
NOT ALLOWED
ALLOWED
METHANE
H
NOT ALLOWED
If the gas distribution network pressure at the installation site differs
from above, inform the gas board and do not turn the appliance on
until the cause and a solution have been found.
Part 2
To convert the gas type, e.g. from natural gas to LPG, the nozzles of
the main burner, by-pass and pilot light have to be changed. All the
nozzles are marked with a number that indicates the diameter in
1/100 and come supplied within a bag.
All appliance connection, installation, and maintenance operations must only be carried out by qualified technicians and in compliance
with all applicable regulations!
BURNER:
Detach the knobs.
Remove the control panel by unscrewing the fixing screws at
the bottom.
Replace the nozzle (fig.5) with a nozzle suited to the new type
of gas indicated in the nozzles table - T1 section Technical
Specifications.
ADJUSTING THE AIR:
Unscrew the fixing screw of the primary air adjustment bush.
Move the bush to the distance "H" (fig.7) indicated in the nozzles
table -T1
Block the bush by tightening the fixing screw.
Evacuation of unburned gases
Checking the pressure
Between 20/25 and 35/45 mbar
Below 20/25 above 35/40 mbar
Between 17 and 25 mbar
Below 17 above 25 mbar
Replacing the nozzles and adjusting the air
The distribution network pressure can be taken using a U-tube
manometer (min. value 0.1 mbar), connected to the pressure outlet
at the base of the appliance "P" (fig.6).
1.
Remove the screw and sealing washer "Y" (fig.6) from the
pressure outlet and connect the manometer.
2.
Turn the appliance on following the enclosed instructions and
check that the pressure is within the permitted pressure range.
3.
Disconnect the manometer and replace the screw "Y" (fig.6) and
the sealing washer in the pressure outlet.
After each conversion or adaptation, the appliance must undergo an
operating test and the supplementary plate must be updated
according to the conversion or adaptation carried out.
PILOT LIGHT:
Unscrew and remove the closing nut (fig.3).
Replace or adjust the pilot nozzle "D" (fig.3) as per the
indications in the nozzles table - T1.
Reassemble the closing nut.
MINIMUM:
Replace or adjust the minimum nozzle "Um" (fig.6) as indicated
in the nozzles table - T1.
Reassemble the panel and the knobs.
GB / IE - 2
Transformation and adaptation