The machine is
There is a voltage drop at the
weak and might
stop when on the
ground.
The machine vi-
The grinding speed is to high Lower the speed
brates a lot
The tools are damaged
5.6.2 Error codes SC-450 NS
Code
Descrip-
tion
A2001
Over cur-
rent
A2002
Over volt-
age
A2003
Under
voltage
7
See access table "Table 02"
64
power supply
Cause
One of the three phases is
missing from the power sup-
ply
There is a voltage drop at the
power supply
The environmental tempera-
ture is too high. When the
temperature is above 40°C
(104°F) the inverter will de-
crease its maximum output
current
The power supply has got
voltage transients
One of the three phases is
missing from the power sup-
ply
There is a voltage drop at the
power supply
Inspect the fuses in the worksites
fuse box
Inspect cables
Measure that the main voltage is
present and at full voltage at the ca-
ble end near the machine.
Make sure that the cable is not too
long. If the cable should be too
long, use a cable with higher rating
to a distribution box nearer the ma-
chine.
Inspect the tools
Change the tools if needed
Correction
Inspect the fuses in the
worksites fuse box
Inspect cables
Measure that all three phases
are present and at full voltage
at the cable end near the ma-
chine
Make sure that the cable
is not to long. If the cable
should be to long, use a ca-
ble with higher rating to a
distribution box nearer the
machine
Inspect the ventilation fans
Inspect the filters to the fans
Inspect the power source
See A2001