3. TIMER 1h-24h:
When the unit is switched on, press the TIMER button first. Now you can set the desired switch-off time
with the up/down buttons.
When the unit is switched off, press the TIMER key to set the switch-on time.
Deactivate Timer: Press the Up/Down button repeatedly until '00' appears on the display.
Note: If you press the POWER button during this time, the timer function will be deactivated.
4. Automatic Frost Protection:
At low room temperatures, frost may accumulate on the evaporator during operation. In this case,
the unit automatically starts defrosting and the POWER LED flashes. The defrost control sequence
is as follows:
- When the unit is operating in cooling mode or dehumidification mode, the ambient temperature
sensor detects the evaporator coil temperature. As soon as this drops below -1°C, the compressor
is switched off. After the compressor has stopped operating for 10 minutes or reaches the coil
temperature 7℃, the unit restarts in cooling mode.
5. Overload Protection:
In the event of a power failure, there is a 3-minute delay until the compressor restarts to protect the
compressor.
Emptying of the water tank
Please switch off the appliance before emptying the water tank.
Remove the plug from the water outlet and keep it in a safe area. Please connect the drain hose securely and
properly and ensure that it is not kinked and free of obstacles. Please place the hose outlet over a drain or
bucket and make sure that the water can escape freely from the unit. Please do not immerse the end of the
hose in water, as this may result in an "air lock" in the hose.
To avoid water leakage:
Since the negative pressure of the condensate tray is high, please tilt the drain hose downwards to the floor. It
is advisable that the inclination exceeds 20 degrees.
Please align the hose to avoid the presence of a air trap in the hose.
Cleaning
Cleaning the housing
1. Press the POWER button to turn off the power and unplug the power cord.
2. Please use a neutral detergent with a soft cloth to clean the exterior surfaces and a dry cloth to dry them
off.
3. Please do not use petrol or other chemical cleaning agents to clean the unit.
Cleaing the air filter (every two weeks)
Dust collects on the filter and restricts the air flow. The restricted airflow reduces the efficiency of the system
and can cause damage to the unit if clogged.
The air filter must be cleaned regularly. The air filter is removable for easy cleaning. Do not operate the unit
without the air filter as this may contaminate the evaporator.
1. Please remove the filter fabric from the unit.
2. Use a vacuum cleaner to remove dust from the filter.
3. Please turn the filter over and rinse the air filter under running water. Let the water flow through the
filter in the opposite direction to the air flow. Set the filter aside and allow it to air dry completely before
reinstalling.
Beware!
Do not touch the surface of the evaporator
with your bare hand as this may cause injury
to fingers.