depending on water quality, room-sealed water heaters can produce a boiling noise; this is normal and does not indicate any defect on the appliance. To
avoid the development of bacteria (legionella...) ensure that a temperature of 60°C is reached every day. The thermostat is set at the factory at the stop
(65°C±5°C).
IMPORTANT: If steam or boiling water emerges continuously from a supply tap or a drain valve, switch off the electricity to the water heater or boiler and call
a professional plumbing contractor.
5°) MAINTENANCE
User maintenance: Operates once a month the discharge of the water safety device to prevent scaling and verify that it is not blocked. If this is not
done, damage may be caused and the guarantee invalidated. For an installation with a booster pump; before starting up, after a long period of disuse, turn
the rotor following the advice in the manufacturer's instructions.
Maintenance by a qualified person:
1/ Remove the scale sludge. Do not scrape or hammer the lime scale deposited on the casing, as this may damage the lining.
2/ Change the magnesium anode every 2 years or when its diameter is lower than 10 mm.
3/ Changing the shielded heating element or the anode requires the water heater to be drained and the joint changed. DRAIN: Switch off the power and cold
water and open the hot water taps before carrying out these operations. Refit the heating element and tighten the screws smoothly (opposite screws in
sequence), check for leaks the next day and tighten if required. If the supply cord is damaged, it must be replaced by a special cord or assembly available
from the manufacturer or its service agent.
Spare parts list: thermostat, joint, heating element, pilot light, the magnesium anode, the connection cable, electric switch. The guarantee requires
genuine manufacturer's parts to be used.
Advice to the user: When the water has a TH > 20°f, it is recommended that this be treated. When a softener is used, the water hardness must remain
above 15°f. In case of prolonged absence, especially in winter, drain your appliance following the procedure.