GiBiDi CB24 Instrucciones Para Las Instalaciones página 7

Ocultar thumbs Ver también para CB24:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 10
CB24
1. Check that the green led D9 turns on showing full battery.
(the led is on even if 24Vac is present and without batteries, showing correct value of charging voltage).
Check, in other way, that the yellow led D7 turns on showing low batteries.
2. Wait for the battery recharge: this action is pointed out by green led that switch to on, and by yellow led that switch
to off in the same time.
SIGNALING
RED LED D6
GREEN LED D9 (bicolor)
YELLOW LED D7
RED LED D12 (bicolor)
DISPOSAL
GI.BI.DI. advises recycling the plastic components and to dispose of them atspecial authorised centres for electronic
components thus protecting the environment from polluting substances.
STATUS ON
Shows the presence of power supply 24Vac
With batteries connected it shows maximum charge.
Without batteries it shows right value of charging
voltage
With motor stopped it shows low batteries.
While motor is running, the led may turning on
because is linked to the current absorption of the
motor and it doesn't means any failure of the
control board.
EMERGENCY. It shows charging voltage is too
much high.
Call the technical assistance.
7