Valve and tubing connections
CONNECT 1/2" DIA. TUBING TO TEE AND SOLENOID ASSEMBLY, TWO PLACES. THE MALE CONNECTOR
A
(FIGURE 10B) FOR THE VALVE ASSEMBLY WILL REMAIN TIGHT AND LEAKPROOF WHEN TUBING IS CUT AND INSTALLED PROPERLY.
FOLLOW THE PROCEDURES BELOW WHEN INSTALLING TUBING TO ENSURE THAT YOU ACHIEVE A LEAKPROOF SEAL.
•
USING A SHARP RAZOR, CUT TUBING SQUARELY AND REMOVE ANY BURRS. DO NOT PINCH OR CRUSH END OF TUBING.
•
LOOSEN NUT ON FITTING. MOISTEN END OF TUBE AND PUSH INTO FITTING UNTIL IT IS FIRMLY SEATED. TIGHTEN NUT TO SECURE
TUBE TO FITTING (MAKE SURE NUT IS SECURELY TIGHTENED).
•
IF CONNECTOR LEAKS, RESEAT TUBING ACCORDING TO ABOVE PROCEDURE. IF LEAKING PERSISTS, REPLACE MALE
CONNECTOR, OR CALL YOUR BRADLEY REPRESENTATIVE FOR ASSISTANCE.
B
HANG VALVE ASSEMBLY ON PEDESTAL BRACKET (SEE FIGURE 11 ON PAGE 17). USE WIRE TIE TO SECURE VALVES.
NOTE!
C
CONNECT THE 1/2" NPT FEMALE END OF THE STOP/CHECK VALVES TO THE ROUGH-INS.
D
ATTACH FLEXIBLE HOSING TO THERMOSTATIC MIXING VALVE, TWO PLACES.
E
INSERT THE FILTER WASHERS (PROVIDED) INTO THE SWIVEL NUT AT THE END OF THE SUPPLY HOSES AND CONNECT TO THE
STOP/CHECK VALVES.
1/2" DIA. TUBE
FROM SPRAYHEAD
1/2" DIA. TUBE
R68-600012
SOLENOID
ASSY.
S08-055
FLEXIBLE
HOSE
FILTER WASHER
STOP/CHECK
VALVE
Figure 10a
16
®
54" Circular
NOTE: Flush supply lines before making connections.
Do not apply pipe sealant to compression fittings.
For "O" and "B" units (overhead supplies) Skip steps C through E
VOLUME CONTROL
S02-045
VALVE ASSEMBLY S50-369
4/6/2007
TEE
269-764
THERMOSTATIC
MIXING VALVE
ASSEMBLY
S67-597
Bradley Corporation • 215-1187 Rev. N; EN 06-915B
NUT
TUBING
MALE TUBE
CONNECTOR
Figure 10b
Installation