CUSTOMER RESPONSIBILITIES TABLE
MAINTENANCE TASK
Check oil level
Change oil
Clean Air Filter Assembly
Check Spark Plug
Check fuel line, hose
clamps and fuel tank
Prepare Unit for Storage
Note 1: Change oil after first two (2) operating hours and every 50 operating
hours thereafter, more often if op er at ed in extreme dusty or dirty condition
Note 2: Check oil after 5 hours of operation.

GENERAL RECOMMENDATIONS

The warranty of the generator does not cover items that have been subjected to
operator abuse or negligence. To receive full value from the warranty, operator
must main tain the generator as instructed in this manual.

ENGINE MAINTENANCE

Refer to the Engine Operator's manual for service and maintenance of the engine.
GENERATOR MAINTENANCE
Your generator should be kept clean and dry at all times. The generator should
not be stored or operated in environments that includes ex ces sive moisture, dust
or any corrosive vapors. If these substances are on the gen er a tor, clean with
a cloth or soft bristle brush. Do not use a garden hose or anything with water
pressure to clean the gen er a tor. Water may enter the cooling air slots and could
pos si bly damage the rotor, stator and the internal wind ings of the generator head.

MAINTENANCE

Before
Every 25
each
Hours
use
of Every
Season
X
See Note 2
X
X
X
Prepare unit for storage if it is to remain idle
for more than 30 days.
15 - ENG
Every 50
Every 100
Hours
Hours
of Every
of Every
Season
Season
See Note 1
X
A16596