(synbol) machine not suitable
for connection to the potable water mains.
CAUTION: - Danger! Only clean or filtered
water should be used for intake. The water
intake should be at least twice the pump
capacity.
-
Minimum delivery rate: 15 l/min
-
Maximum intake water temperature: 40°C
-
Max inlet water pressure: 1Mpa
Place the cleaner as close as possible to the
water supply.
Water supply from the water main
Connect a supply hose (not included) to
the water inlet of the unit and to the water
supply.
Open the water supply.
The cleaner can be connected directly to the
mains drinking water supply only if the supply
hose is fitted with a backflow preventer valve
as per current regulations in force.
Make sure that the hose is at least Ø 13mm
and that it is reinforced.
: Water that has flown through
backflow preventers is considered to be
nonpotable.
Water supply from an open container
Unscrew the coupling part for the water
inlet.
Screw the suction hose with filter (not in-
cluded) onto the water connection of the
unit.
Hang the filter in the container.
Vent the unit before operation.
-
Unscrew the high-pressure line at the
high-pressure outlet of the unit.
-
Switch on the unit and let it run until
water free of bubbles emerges at the
high-pressure outlet.
-
Switch off the unit and screw on the
high-pressure hose again.
Failure to comply with the above conditions
causes serious mechanical damage to the
16
pump and the loss of warranty cover.
1. Connect the high pressure hose to the unit's
high pressure outlet (fig. 5).
fig. 5
2. Connect the high pressure hose to the spray
gun. Insert the spray wand of your choice into
the wand extension. Press in against the spring
tension and twist into the locked position (fig.
6).
fig. 6
3. Connect garden hose to unit's water inlet
(Max 10 bar, max t. 40° C) (fig. 7).
fig. 7
4.Connect garden hose to the cold water
source and turn water on completely (fig. 8).
5. Trigger the gun to eliminate trapped air,
wait for a steady flow of water to emerge from
the spray nozzle (fig. 9).
fig. 9
CAUTION: In order to assist the first startup,
it is recommended to hold the trigger
pressed during the pulling of the starter

Publicidad